Table 5. Nozzle Flow Rate by Size
Nozzle fl ow rate U. S. gallons per hour of No. 2 fuel oil when
pump pressure (psig) is:
Nozzle
125
140 psi
size
psi
(rated at
100 psig)
0.45
0.47
0.40
0.56
0.59
0.50
0.67
0.71
0.60
0.73
0.77
0.65
0.84
0.89
0.75
0.95
1.01
0.85
1.01
1.07
0.90
1.12
1.18
1.00
1.23
1.30
1.10
1.34
1.42
1.20
1.39
1.48
1.25
1.51
1.60
1.35
1.68
1.77
1.50
1.84
1.95
1.65
1.96
2.07
1.75
2.24
2.37
2.00
2.52
2.66
2.25
2.80
2.96
2.50
Attach air tube (if not already installed)
If using a fl ange and gasket, slide them onto the air
tube. Then attach the air tube to the burner chassis
using the four sheet metal screws provided. Refer
to Figure 3 for details.
Install burner nozzle (if not already in-
stalled)
1.
Remove the plastic plug protecting the nozzle
adapter threads
2.
Place a ¾" open-end wrench on the nozzle adapter.
Insert the nozzle into the adapter and fi nger tighten.
Finish tightening with a ⅝" open-end wrench. Use
care to avoid bending the burner head support legs
or electrodes. If you remove the head to replace
the nozzle (type "L1"/"L2" or "V1" heads), carefully
reconnect the head to the nozzle adapter, making
sure that the head support makes contact with the
nozzle adapter shoulder. Refer to Figure 4 or 5.
Table 6. Nozzle Spray Angles
Recommended nozzle spray angles
"F" head
"L1" & "L2" head
"V1" head
RWB 6104 BAFG R02
150 psi
175 psi
200 psi
0.49
0.53
0.61
0.66
0.74
0.79
0.80
0.86
0.92
0.99
1.04
1.13
1.10
1.19
1.23
1.32
1.35
1.46
1.47
1.59
1.53
1.65
1.65
1.79
1.84
1.98
2.02
2.18
2.14
2.32
2.45
2.65
2.76
2.98
-
-
70° or 80° nozzle
45°, 60°, or 70° nozzle
45°, 60°, or 70° nozzle
3.
If the nozzle is already installed, remove the noz-
zle line assembly to verify that the nozzle size and
spray pattern are correct for the application (per ap-
pliance manufacturer's information). Verify that the
electrode tip settings comply with Figure 2.
4.
If the nozzle is not installed, obtain a nozzle from
the manufacturer, having the capacity and spray
0.56
angle specifi ed in the appliance manufacturer's in-
0.71
formation. For conversions or upgrades, when in-
0.85
formation is not available for the application:
Refer to Table 6 to select the mid-range nozzle
0.92
spray angle for the head type being used.
1.06
Fire the burner and make sure the combustion
1.20
is acceptable and the fl ame is not impinging on
1.27
chamber surfaces.
1.41
If a shorter fl ame is needed, select a wider spray
1.56
angle. If a longer fl ame is needed, select a nar-
1.70
rower spray angle.
Either hollow or solid spray patterns may be used.
1.77
If combustion results are not satisfactory with the
1.91
selected spray pattern, try the other pattern.
2.12
2.33
Check/adjust electrodes
2.48
Check the electrode tip settings. Adjust if neces-
2.83
sary to comply with the dimensions shown in Fig-
-
ure 2. To adjust, loosen the electrode clamp screw
and slide/rotate electrodes as necessary. Securely
-
tighten the clamp screw when fi nished.
Figure 2. – Electrode Tip Adjustment
Standard Dimensions for F, L1, and V1 Heads.
The Dimensions shown below are for use with L2 heads
and M series air tube combinations ending with an 'N' suf-
fi x (example: AFG70MDAQ
)
N
Page 7