8.4.5 Auto Volume does not calibrate
Auto Volume calibration may fail if the process cannot obtain an
adequate source level. This may be due to:
• Speakers are tapped too high
• Maximum output gain is less than -20 dB
• Source is not operating
• Source level is too low
Calibration could also fail if the calculated loop gain is not within
required limits. This may be due to:
• Broken microphone cable
• Speakers are not connected
• Sensing microphone is not connected, or is connected to the
wrong zone
8.5 Customer support
8.5.1 Technical assistance
If you need further technical assistance, contact your local Bose
representative, or send an email to the address for your area:
North America
Europe
Asia, Australia, India and Middle East
8.0 E4 System Troubleshooting
70 of 80
8.5.2 Reporting software bugs and issues
Please email any problems, issues, or software bugs to your local
Bose representative. Please include the following information:
• Software version
• E4 Error Log file
• Computer make, model, and configuration (hard drive storage
capacity, processor speed, and amount of installed RAM)
• Description of the problem – Can it be reproduced? If so, what
steps can be taken within the application to make the problem
manifest itself?
If possible, attach the Installer™ software diagnostic files. The
Installer software creates three important diagnostic files (output,
error, and log) each time the software runs. These files are distinct
from the E4 Error Log file which refers to the hardware errors and
can be accessed using the Service tab within the Installer™ soft-
ware.
The name of each Installer diagnostic file includes the date and
time that Installer software was run. For example:
FreeSpaceInstallerOutput-Oct 8, 2002 12_53_05 PM.txt
FreeSpaceInstallerErrors-Oct 8, 2002 12_53_05 PM.txt
FreeSpaceInstallerLog-Oct 8, 2002 12_53_05 PM.txt
These files are automatically written in the "temporary file" direc-
tory of your computer's operating system. Use the standard Win-
dows "Search" of "Find" feature to look for files named
FreeSpaceInstallerOutput
FreeSpaceInstallerErrors
FreeSpaceInstallerLog
on all local hard drives. This feature can be found in the Start
menu of Windows 98, NT, 2000, or XP. Once the search is com-
plete, sort the listing by date to show the diagnostic files most
recently created by the Installer™ software.
,