EXCEL-FIRE GAS STOVE

Pilot assembly

Adjusting air shutter (Venturi)
The factory setting for the air shutter is 1/4" for natural gas, fuily open for propane. After operating
the appliance for half an hour or so the flames should have turned a nice yellow colour. However,
in higher altitudes you may find a smudging up of the glass after a few days. The shutter should
then be adjusted open in 1/16" increments until the glass stays clear. If the flame does not turn
yellow the air shutter should be closed until the flame just turns yellow. To access the shutter you
need to remove the glass front, the logs and grate. Lift out the hearth surrounding the burner and
the shutter will be exposed underneath. Loosen the retaining screw 1 turn before attempting to
move the shutter.

OPTIONS

ITEM DESCRIPTION
• Wall thermostat kit
• 130 CFM blower kit with variable speed control

REPLACEMENT PARTS

ITEM DESCRIPTION
• 6'' stove pipe adapter
• Set of logs 5
• Burner (natural gas or propane)
• Pyroceram Glass (19.446" x 11.737")
• 1/2" dia. gasket for door
• U gasket for glass
• Blower 130 cfm
• Variable speed control
• Thermo-switch (for blower)
• Gas valve (natural gas) SIT
• Gas valve (propane) SIT
• Pilot assembly (natural gas) SIT
• Pilot assembly (propane) SIT
• Piezo igniter
• Burner orifice (natural gas #36)
• Burner orifice (propane #52)
• Thermocouple
• Spill switch
• Thermopile
Part no
AC05558
AC05914
Part no
SE9348
AC05791
SE09311-01
SE09335-05
40020
40005
44070
44080
44044
49133
49126
49103
49106
49128
9071
9071-01
49122
44047
49095
13