3. PRODUCT IDENTIFICATION
There is a plate on the side of the unit that displays the product code, the power supply voltages and the basic
characteristics.
4. TECHNICAL SPECIFICATIONS
Reservoir capacity
Maximum number of modules
Air inlet pressure
Maximum air consumption at the outlet
Air inlet pipe
Air outlet pipe
Oil outlet pipe
Oil flow rate per element
Lubricating oil
Protection grade of module
Protection grade of reservoir
Pressure switch calibration (optional)
Maximum pressure switch load (optional)
Maximum minimum level load
Element solenoid valve power supply
Operating temperature
Storage temperature
Max. relative humidity without operating condensate
Sound pressure level
Net weight
5. COMPONENTS
Air regulation
Pressure gauge
(optional)
Push-in pipe Ø6 air
outlet
Push-in pipe Ø3 oil
outlet
TECHNICAL SPECIFICATIONS
PRO
BASE
CART
Standard
i
"
"
-
On request (special)
MODULAR ELEMENT
1lt – 3lt
8
4bar ÷ 7bar
~50Nl/min (per module)
Ø10mm
Ø6mm
Ø3mm
0.1
÷
2.7 cc/min
0
÷
1 cc/min
0
÷
0.2 cc/min
0.3
÷
8 cc/min
0.1
÷
3 cc/min
0
÷
0.6 cc/min
cc/min = (P x 8.16)/V
P = Operating pressure in [bar]
V = viscosity [Engler] at operating temperature
10cSt ÷ 100cSt
IP 00
IP 65
IP 65
6bar
Voltage free contact maximum voltage 250V
Maximum power 100W
0.2A @ 30V
24Vdc
+5°C ÷ +50°C
-10°C ÷ +80°C
90%
< 70 dB(A)
~5Kg (mod. 1lt) – ~7Kg (mod. 3lt)
(oil 10cSt)
(oil 32cSt)
(oil 100cSt)
(oil 10cSt)
(oil 32cSt)
(oil 100cSt)
Solenoid valve
i
("-
" version only)
Oil regulation
(NO "CART"
version)
Compensation valve
)
("PRO" version only
3