DRY AGER DX 1000 Manual del usuario - Página 3
Navegue en línea o descargue pdf Manual del usuario para Frigorífico DRY AGER DX 1000. DRY AGER DX 1000 14 páginas.
También para DRY AGER DX 1000: Manual de instrucciones (17 páginas)
Climate class
The climate class indicates the ambient temperature at which the unit
may be operated in order to achieve full cooling capacity.
• The climate class is printed on the type plate.
• The position of the type plate can be seen in the chapter Unit
description (page 6).
max. rel.
max. ambient
Climate class
temperature
humidity
7
35 °C
75 %
The minimum permissible ambient temperature at the installation
site is 10 °C.
Do not use the unit outside the specified
ambient temperatures!
Energy saving
• Always ensure good ventilation. Do not cover ventilation openings
or ventilation grilles.
• Always keep fan ventilation slits clear.
• Do not set up the unit in an area of direct sunlight, next to a stove,
heater or similar.
• The energy consumption depends on the installation conditions
such as the ambient temperature.
• Open the unit for as short as time as possible.
Dust deposits increase energy consumption:
Clean away dust from the chiller with the heat exchanger (metal grille
at the back of the unit) once a year.
Power connection
The unit is only to be operated using AC power only.
• The permissible voltage and frequency are printed on the type
plate. The position of the type plate can be seen in the chapter
Unit description (page 6).
• The socket must be properly grounded and electrically fused.
• The tripping current of the fuse must be between 10 A and 16 A.
• The socket must not be behind the unit and must be easily accessi-
ble.
• Do not connect the unit using extension cords or distribution sockets.
• Do not use stand-alone inverters (converting
direct current into alternating or three-
phase current) or energy-saving plugs. Risk
of damage to the electronics!
Noise emission
The noise level during operation of the unit is below 70 dB(A) (sound
power rel. to 1 pW).
4
Disposal information
The unit contains valuable materials and must be
disposed of separately from unsorted municipal waste.
Disposal of disused units must be carried out profes-
sionally and appropriately in accordance with the locally
applicable regulations and laws.
Do not damage the refrigeration circuit of the disused unit when
removing it, to ensure that the refrigerant contained (information on
the type plate) and the oil cannot escape in an uncontrolled manner.
• Pull out the power plug
• Cut through the connection cable
• Make the unit unusable
WARNING
Danger of suffocation from packaging material
and foils! Do not let children play with packag-
ing material. Take the packaging material to an
official collection point.
Area of application of the unit
The unit is only suitable for cooling/conditioning meat or
food in domestic or household-like environments and busi-
nesses.
All other types of application are not permitted. The unit is not
suitable for the storage and cooling of medications, blood plasma,
laboratory preparations or similar substances and products that are
subject to the Medical Device Directive 2007/47/EC. Improper use of
the unit can lead to damage to the stored goods or their spoilage.
Furthermore, the unit is not suitable for operation in potentially ex-
plosive areas, outdoors or in areas with moisture and splashing water.
The unit complies with the relevant safety regulations as well as the
EU directives 2006/42/EC, 2014/30/EU, 2011/65/EU.
Setting up the unit
• Do not set up the unit in an area of direct sunlight, next to a stove,
heater or similar.
• The floor at the set-up location should be horizontal and even.
Compensate for unevenness using the adjustable feet.
• Do not cover ventilation openings
or ventilation grilles.
• According to the EN 378 standard, the instal-
lation room of the unit must have a volume
of 1 m
3
per 8 g of refrigerant charge R600a, so
that in the event of a leakage of the refrigerant
circuit, no ignitable gas-air mixture can de-
velop in the installation room of the unit. The
refrigerant quantity is indicated on the type
plate inside the unit (page 14).
• Always install the unit directly against the wall
or install it professionally.
• Place the unit in its final position at the
installation location. Unscrew the adjustable
foot at the lower hinge bracket until it rests
on the floor, then turn it a further 90°.
Quick starter tips
These quick starter tips do not replace the detailed operating, warning and hazard information in the other chapters
of the instructions for use.
General Information
1.
Clean the interior of the unit. It is best to clean with DRY AGER®
Special Cleaner, item no. Z33145. After each completed aging pro-
cess, also activate the pre-cleaning program (P16) in addition to the
spray cleaner. Duration: 2 hours.
2.
When ordered: Unpack the salt blocks (remove the foil)
and place the blocks in the stainless steel tray. Center the tray
on the floor. If liquid is produced, empty the tray. Ideally, check
every 2 - 3 days.
3.
Plug the unit into a 220-240 V outlet and do not use a
multiple outlet.
4.
The DRY AGER® Premium S series cabinet can be operated in
two different modes:
Standard mode
The display shows the values for temperature and humidity. These
can be set in the range between 0 - / +30 °C and 40 to 90 % rH. The
factory setting at start-up is 1.5 °C and 82 % humidity. This setting is
ideal for dry aging beef or pork. Further details on using the Stan-
dard mode can be found from page 11.
SmartAging® mode
The SmartAging® program ("PG" + program number) and the tem-
perature are shown in the display. Well-thought-out aging programs
developed by professionals let you age to perfection. The appropri-
ate program number is selected (see SmartAging® program selec-
tion, page 15), set in the controller and you are ready to go. Details
on the use of the SmartAging® mode can be found from page 12.
5.
Always wear protective gloves when coming into contact with
the product. Likewise when buying, pay attention to how the seller
treats the goods.
6.
The activated carbon filter and the UVC lamp must be re-
placed annually for the unit to function properly. A maintenance
message appears on the display before the end of the service life
(see Maintenance, page 14).
Tips for meat
Meat is by far the most common dry-aged product, so here are a
few special tips:
1.
Meat for dry aging must be fresh, ideally max. 5 days after
slaughter. Meat from vacuum bags can also be aged; the appropriate
aging program can be found from page 16 onwards.
Tip for Dry Aged Beef: Use saddles from a heifer and look for good
marbling and fat cover.
2.
Hang saddles of beef on the hook in the DRY AGER® cabinet
or place cuts on the optional shelves.
3.
Loading capacity with hangers: A maximum of 3 x saddles up
to 20 - 22 kg each fit into the units, 2 hangers are required for this.
4.
Loading capacity with shelves (optional): A maximum of
100 kg pieces or cuts fit on a total of four shelves. When dry aging
meat on the shelves, ensure that the fat is well covered and, if
possible, mature on the bone.
5.
Ideal aging times are 21-28 days, but an aging time of over
4 weeks is also possible. The taste of the meat then becomes even
more intense.
Tip: It is essential to use the functional scope of the integrated
SmartAging® technology here in order to make the correct fully
automatic setting. Details on that from page 12.
The Dry Aging Bible
Further tips on other foods such as sau-
sage, ham, fish, cheese, vegetables and
much more can be found in the book
The Dry Aging Bible - the ultimate stan-
dard work for operating this cabinet.
5