Dry:Soon 21736 Manual de instrucciones - Página 9

Navegue en línea o descargue pdf Manual de instrucciones para Bastidores y soportes Dry:Soon 21736. Dry:Soon 21736 12 páginas. 3 tier heated airer

ELECTRICAL CONNECTIONS

THIS APPLIANCE MUST BE EARTHED
This appliance is fitted with a fused three-pin plug to BS1363 which is suitable for use
in all homes fitted with sockets to current specifications. If the fitted plug is not suitable
for your socket outlets, it should be cut off and carefully disposed of. To avoid an electric
shock, do not insert the discarded plug into a socket.
FITTING A NEW PLUG
If for any reason you need to fit a new plug, the flexible mains lead must be connected
as shown here. The wires in the mains lead fitted to this appliance are coloured in
accordance with the following code:
If the colours of the wires in the mains lead of this appliance do not correspond with the
coloured markings identifying the terminals in your plug, proceed as follows. The wire
which is coloured green and yellow MUST be connected to the terminal which is marked
with the letter E (Earth) or coloured green. The wire which is coloured blue MUST be
connected to the terminal which is marked with the letter N (Neutral) or coloured black.
The wire which is coloured brown MUST be connected to the terminal which is marked
with the letter L (Live) or coloured red.
Before refitting the plug cover, check that there are no cut or stray strands of wire inside
the plug. Use a 3 amp BS1362 fuse. Only BSI or ASTA approved fuses should be used. If
you are at all unsure which plug or fuse to use, always refer to a qualified electrician.
Note: After replacing or changing a fuse on a moulded plug which has a fuse cover, the
cover must be refitted to the plug; the appliance must not be used without a fuse cover.
If lost, replacement fuse covers can be obtained from an electrical shop. This appliance
complies with the following EU Directives: 2014/35/EU (Low Voltage Directive) and
2014/30/EU (EMC Directive).

RECYCLING YOUR ELECTRICALS

Along with many other high street retailers, Lakeland has joined a
scheme whereby customers can take their unwanted electricals to
recycling points set up around the country.
Visit www.recycle-more.co.uk to find your nearest recycling point.
3 amp
fuse
Connect BLUE to Neutral (N)
3 amp FUSE
Connect GREEN/YELLOW to Earth (E)
Connect BROWN to Live (L)
3 amp fuse to be used