Mechanical Drive Components

Access to the internal mechanical drive components is through the access door. This door must be removed.
Electric Motor
(5-1)
The electric motor used to drive the reel is manufactured by Marathon Electric.
No regular maintenance is required.
Make sure that, during operation or storage, the motor is not in prolonged
contact with moisture.
Refer to the chart "Table 1- Electric motor features & data", below for motor
data.
Note: This motor has no built-in thermal protection. Thermal protection is provided by
the "ALTIVAR 11 Drive Controller".
Table 1 - Electric motor features & data
Product Feature
Model Number:
56T17F5310
Catalog Number: G527
Product Type:
SQ CAGE IND RUN Insulation Class:
Enclosure:
TEFC
Frame:
56C
HP/KW:
1
Frequency (HZ):
60
Speed (RPM):
1800
Mounting:
ROUND
Motor Wt.:
26
Mechanical Information
Shaft Material:
STANDARD
Enclosure:
TEFC
Frame:
56C
Frame Material:
Rolled Steel
Shaft:
T
Grease:
STANDARD
Gear Box
(6-1)
Gear box specifications
HUB CITY - Series 260, Model 264 (FR-56C-70)
Worm gear speed reducer
60:1 gear reduction
5/8" input shaft size
1 1/8" output shaft
CAUTION
Do not operate the unit without ensuring it contains the correct amount of oil. Do not overfill or underfill with oil. Injury to personnel,
unit, or other equipment may result.
Oil should be changed with greater frequency if unit is used in severe environment (dusty or high humidity).
WARNING
Oil, housing, and other components can reach high temperatures during operation, and can cause severe burns. Use extreme care when
removing lubrication plugs and vents while servicing the unit.
See "Maintenance - Gear Box" section of the operators manual for Hub City Gear Box oil filling procedures, service & maintenance.
Setup/Operation
Phase:
3
Volts:
208-230/460
B
F.L. Amps:
3.4-3.6/1.8
Duty:
CONTINUOUS
Service Factor:
1.15
F.L. Eff.:
77
Bearing:
BALL/BALL
Thermal Protection:
NONE
Hazardous Location: NONE
Mounting:
ROUND
Electrical Type:
STANDARD
Spaceheaters:
NONE
Orientation:
Horizontal
Conduit Assembly:
F1
5-1
5 - Marathon electric motor
6-1
6 - Hub City gear box
4-3