Anolis ArcPower 36 Manual del usuario - Página 6
Navegue en línea o descargue pdf Manual del usuario para Equipos de iluminación Anolis ArcPower 36. Anolis ArcPower 36 19 páginas.
2.RJ45 patch cables category 5 that connect the ArcPower 36 each other are wired 1:1,that is,pins with the
same numbers are connected together.
Pin 1: Not used
Pin 2: Not used
Pin 3: Not used
Pin 4: Not used
Pin 5: +5V
Pin 6: Data +
Pin 7: Data -
Pin 8: GND
5.Installing instructions.
5.1.DMX operating
1.Unplug from the mains before installation.
2.Connect the LED modules to the fixture.
3.Connect DMX controller to the fixture
4.Connect the fixture to the mains
5.Set the DMX address on the control board of the fixture (see chapter "Control board").
Accidental connection DMX 512 Input/Output to non-DMX 512 device (e.g.Ethernet
Maximum total cable length between Arcpower 36 and all connected LED modules
Single ArcPower 36 installation:
Multiple ArcPower 36 installation:
Connect the DMX output of the first ArcPower 36 with the DMX input of the next ArcPower 36. Always connect
one output with the input of the next ArcPower 36 until all fixtures are connected.In this way,up to 32 fixtures
can be chained together.
At the last ArcPower 36 the data link has to be terminated with a terminator. A termination plug is simply a
RJ45 connector with a 120
of the last ArcPower 36.
Maximum number of LEDs connected to the one ArcPower 36 is 42 (but maximum12 LEDs per colour).
Warning!
network Hub) can damage the ArcPower 36.
is 80 metres.
Ω
resistor between pins Data (–) and Data (+).Plug terminator in the DMX output
6
Pin 1: Not used
Pin 2: Not used
Pin 3: Not used
Pin 4: Not used
Pin 5: +5V
Pin 6: Data +
Pin 7: Data -
Pin 8: GND