SPECIFICATIONS

Model
Voltage
Power
Min. Required Circuit Breaker Size
Max. Amperage
Recommended Wire Size
Min. Water Flow to Activate the Unit
Safe Operating Pressure
Water Connections
Installation
Temperature Setting
Dimensions (LxWxH)
Weight
Remarks:
1. The above wire size and circuit breaker size are for this EVT-9K unit only. If you need other
high-power appliances, please do further research for that.
2. For the best user experience, the EVT-9K unit is recommended for sink use and as a booster
for tank water heaters.
SIZING GUIDE
Please use the chart below to see how many gallons per minute your tankless water heater can
produce with your incoming water temperature. The gallons per minute is calculated assuming
108°F outlet temperature.
Model
Inlet Temp (°F)
EVT-9K
4
GPM
41
0.9
50
1.0
59
1.2
68
1.5
77
2.0
EVT-9K
240 V
9.0 kW
40 AMP
37.5 A
8 AWG
0.475 GPM / 1.8 L/min
7.25 PSI - 108.78 PSI
1/2'' NPT
Wall Mounted
Digital Panel
16.14'' x 9.84'' x 2.60''
8.8 Lbs
Suggested Usage
Outlet Temperature (°F)
Low Flow Faucet
Bathroom Faucet
Bathroom Faucet
Kitchen Faucet
Shower
108