DRYDEN AQUA 90026 Manual de instrucciones - Página 12

Navegue en línea o descargue pdf Manual de instrucciones para Instrumentos de medida DRYDEN AQUA 90026. DRYDEN AQUA 90026 20 páginas.

DRYDEN AQUA 90026 Manual de instrucciones

11. Operation

After setting the DIP Switches to reflect the FlowVis model and Pipe Size employed in your application, the FlowVis Digital
is ready to use. No calibration or further settings are required. However, by default, the FlowVis Digital readout will display
the flow rate in US GPM and the Turnover Rate will show --- (indicating that this function is not activated). If you would like to
change the unit of measurement from US GPM to either LPM or M3/hr, and /or activate the pool Turnover Rate function, then it
will be necessary to access these functions as described in the Advanced Setup section.

12. Advanced setup

Although FlowVis Digital will function as a flow meter without additional steps, there are several very useful features that can
be accessed via the 'advanced setup' procedures. These features comprise:
Display of the pool turnover rate
Changing the display's appearance at a user-defined flow rate
Programming an (optional) auxiliary relay to operate external equipment such as a Heater or Chemical Feed System,
which will only operate at user defined flow rates
Programming the advanced features will require a Windows-based laptop PC. The initial step is to download the Advanced
Panel Display Software from the internet, we recommend that this be done in an office environment rather than the pool
equipment room. Note: there is no requirement to connect the laptop to the Display during this initial step.
The laptop PC will require the following:
Running either a Windows 7, 8, or 10 operating system, using either a 32 or 64-bit configuration
Microsoft .NET Framework (if you don't have this, it can be downloaded from www.microsoft.com/net)
A spare USB 2.0 port (for later connection to the Display)
An internet connection
12