Daikin FTM50JV14 Manual de servicio - Página 12

Navegue en línea o descargue pdf Manual de servicio para Climatizadores Daikin FTM50JV14. Daikin FTM50JV14 20 páginas. Removal procedure, 5.0/6.0/7.1 kw class, 15000/18000 btu/h class
También para Daikin FTM50JV14: Manual de servicio (20 páginas)

Daikin FTM50JV14 Manual de servicio

PCBs

7. PCBs
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
1
Remove the screw on
the electrical box.
2
Unfasten the hook and
remove the shield plate.
3
Unfasten the 2 hooks
on the top and remove
the signal receiver unit.
10
All manuals and user guides at all-guides.com
Procedure
Electrical box
Shield
plate
Hook
Signal receiver
unit
Points
(R17747)
The shield plate also has 2
hooks on the upper side (at
the back).
(R13224)
(R2781)
Removal Procedure
Si041254EE