DAITEM SH146AX Manual de instalación - Página 6

Navegue en línea o descargue pdf Manual de instalación para Sistema de seguridad DAITEM SH146AX. DAITEM SH146AX 18 páginas. External detector antimask

GB

4. Parameter-setting

The motion detector is factory-
configured for a deterrence (see
your control panel installation
guide for system responses). The
alarm level can be changed by
resetting the parameters as
shown opposite.
Parameter-setting example:
setting the detector to full ) prealarm :
parameter number 5, parameter value 2.
Parameter-setting
Parameter n°
sequence
5
Programming
LED on
Programming
LED off
about 10 s.
Programming
sequence
Test
Press the
To start,
button
press and
button 5 times
hold until the
for the
LED goes out
parameter
number
5
Press the
Press
Start
button 5 times
once
to select the
to create
alarm level
a space
76
Alarm level
Parameter value
Intrusion
1
Prealarm
2
Deterrence
3 (factory setting)
Warning
4 (the feature is available using control panels
with 2.0.0 version software or later)
about
5 s.
Press and
Press the button
To end,
hold until the
press and
1 to 4 times
LED briefly
for the parameter
hold the
goes out
value
button until
the LED goes
out
2
about 2 s.
Press the button
End
twice to select the
prealarm
about 10 s.
about 2 s.
Programming LED
permanently on =
parameter set
correctly