4.2 Programming for use with the dialler
IMPORTANT: the pendant cannot be recognised directly by a dialler alone SH511AX, SH512AX, SH513AX and SH514AX.
The pendant is only programmed
to operate with a dialler when
there is no alarm control panel in
the system.
1. To perform the pendant
programming operation, the
dialler must be in installation
mode. If it is not, enter:
master code
then
installer code
ADVICE: before doing anything, study
the step 2 programming sequence.
Check the programming LED making
sure to press the push-button for the
required amount of time.
2. Perform the next programming step:
LED ON
LED OFF
y
después
2. Press and hold the pendant
1. Press
then #
*
push-button until the dialler
on the dialler
responds.
keypad
IMPORTANT: the dialler indicates a programming error by issuing 3 short
beeps. When this happens, perform programming again from the start.
8
2 s.
10 s max.
3. The dialler issues
"beep,
command X"
a voice message
to confirm
pendant
programming.