1
On the 1st line of the table below tick the boxes corresponding to the
installation radio code of the control panel (a cross for each microswitches
in OFF position).
customised radio code
detector code
2
On the 2nd line mark "0" (zero) below each tick.
3
Enter "1" (one) in the empty boxes on the 2nd line.
Example (not to be used): the switches 2, 7 and 8 are in OFF position.
customised radio code
detector code
You now have a series of 10 digits made up of "0" and "1" corresponding to
your detector's installation radio code.
Warning: code 0000000000 is not recommended.
4
Programme the radio code by pressing keys 0 and 1 on the detector as
shown below:
Start of programming
1
0
1
1
0
Press both keys at
Briefly press the keys 10 times
the same time until
for your installation radio code.
the light indicator
The red light indicator comes
goes out.
on each time a key is pressed.
Warning: If during programming more than 7 seconds elapse between
pressing 2 keys or if you do not press simultaneously or long enough
keys 0 and 1 at the beginning or end of programming, you will leave the
programming mode. The red light indicator then flashes to show that pro-
gramming is not correct. The initially programmed code is kept, and you
must repeat the operation from the beginning.
5
Installation radio code test (fig. E)
If you are adding to your system, you should first activate the system's test
mode to carry out this test. To do this, refer to the installation guide for the
alarm system provided with the unit.
Briefly press the detector's test button and check that the unit emits an
audio message while lighting up the indicator corresponding to the zone.
16
1
2
3
4
5
6
7
X
X
1
2
3
4
5
6
7
X
X
1
0
1
1
1
1
0
End of programming
Programming
1
1
1
0
0
1
1
0
L
Press both keys at the same time
until the light indicator goes out.
The light indicator then comes
on for 5 sec. to indicate
that programming is OK.
If the control panel does not properly respond, first recode the detector.
Then if the problem persists, recode the control panel and try again.
You have now assigned the detector its installation radio code.
G
Programming the zone and sensitivity (fig. D)
8
9
10
The zone 1 detector is factory-set to normal sensitivity.
X
These settings can be modified in accordance with the table below.
The last digit of the code allows the sensitivity to be set:
-
for maximum sensitivity (the detector transmits the intrusion alarm on the
0
first detection)
-
for normal sensitivity (the detector transmits the intrusion alarm after the
1
second detection: avoids false detections in large rooms).
8
9
10
Zone
X
0
1
1
Immediate tripping
Zone 1
Immediate or delayed tripping
Zone 2
Immediate tripping
Zone 3
1
Immediate or delayed tripping
Zone 4
1
Assign the detector the chosen zone by programming the relevant code
(series of 3 digits made up of "0" and "1"), pressing the keys as shown
below:
Start of programming
0
Press both keys at
the same time until
the light indicator
goes out.
Functionning
Programming
1
1
1
1
0
L
Briefly press the keys
3 times for your
Press both keys at
group code. The
the same time
light indicator
again until the light
comes on each time
indicator goes out
a key is pressed.
GB
Group
Choice
code
of sensitivity
0
0
0
Maximum sensitivity
0
0
1
Normal sensitivity
0
1
0
Maximum sensitivity
0
1
1
Normal sensitivity
1
0
0
Maximum sensitivity
1
0
1
Normal sensitivity
1
1
0
Maximum sensitivity
1
1
1
Normal sensitivity
End of programming
0
1
0
Press both keys at the same time
until the light indicator goes out.
The light indicator then comes
on for 5 sec. to indicate
that programming is OK.
17