Example 4, connection of a roller shutter blind sensor
(mainly used in the continent and not the UK)
To ensure detector radio range:
• do not run the roller shutter blind wire along the detector,
• change the cable path and/or its length if the radio range is not satisfactory.
IMPORTANT: connecting a roller shutter blind sensor does not ensure anti-tamper
protection of the loop.
6. Installing

6.1 Choosing the best place

IMPORTANT
• Make sure there is a distance of at least 2 meters between
each product, except between 2 detectors.
• When the detector is fixed to a metal support, insert a
20 mm thick wooden or plastic spacer between the base
and the metal frame.

6.2 Fixing method

Fix the back plate to the wall using 2 screws suitable for wall fixing.
Before closing the detector cover, choose a cable grommet to match the cable cross-section (see following diagrams).
Cable grommets
4 assembly
options

6.3 Installing the magnet holder

When the entrance is closed the magnet holder must be positioned opposite the built-in contact less than 5 mm away
from it.
1. Align the vertical slot on the magnet holder with the
arrow located on the base of the detector.
slot-arrow alignment
IMPORTANT: The parts must be laterally aligned and their
height adjusted for the detector to operate correctly.
5 mm
max.
70 mm
5
The multicontact detector must be placed:
• inside the protected area,
• preferably on the door frame of the entrance to be
protected at least 1 m above ground level,
• far away from any sources of interference (electricity meter,
metallic frame, etc.),
• on a flat surface.
Position the screw cover
(delivered with the magnet
holder assembly) on the
detector cover.
2. Adjust the height of
the magnet holder
according to the
diagrams below.
1 2 3
Screw cover
5 mm
max.
Magnet holder
Detector
Spacers
Spacer