To test the detector:
• press the test button and the detector changes to test mode for about 90 sec.
After this period the detector automatically returns to normal operating mode,
• check detection of protected entrance opening and closing:
- entrance open: the test LED indicator lamp lights up,
- entrance closed: the test LED indicator lamp goes out.
Pressing on the button for more than 1 sec. causes the control panel to give a
"Test" message when the panel is in test or installation mode.
6. Maintenance
6.1 Battery low indication
The control panel indicates when the contact detector's battery is low.
To check whether there is a problem with the detector battery, press on the detector's test button.
IMPORTANT: if the test LED indicator lamp no longer lights up, the lithium battery should be replaced.
6.2 Changing the battery
• The lithium battery pack must be replaced by the same type of pack with the same technical characteristics
(BatLi31 3 V - 1 Ah).
• We advise you to use the DAITEM BatLi31 pack available in the catalogue in order to guarantee individual
safety and equipment reliability.
• Dispose of the waste lithium power pack in an appropriate recycling bin.
To change the battery:
1. Switch the control panel to installation mode and ask the master user to press:
master code
The detector's configuration is saved when the battery is changed.
2. Open the detector casing (see § on Opening).
3. Unclip the lithium battery pack.
4. Wait 2 min. before replacing the flat lithium battery.
5. Close the detector.
6. Switch the control panel back to user mode. Press:
engineer
installer code
7. Technical data
Specifications
Built-in magnetic contact
Environment
Power supply
Battery life
Average humidity rate
Radio links
Test button
LED Indicator lamp
Operating temperature
Anti-tamper & protection
Degrees of mechanical
protection
Dimensions L x W x H
Weight (with battery)
then
engineer
installer code
"beep, date,
time, off"
Contact detector
1
building interior
DAITEM 3 V lithium battery (BatLi 31)
5 years in normal conditions of use
5% to 75% without condensation at 25°C
TwinBand
®
400/800 MHz
programming, battery and detection test
1
-10 °C to +55 °C
• against opening and removal
• against loop cutting
IP 31/IK 04
108 x 26 x 30 mm
60 g
"beep, installation
mode"
DECLARATION OF CONFORMITY
Manufacturer: Hager Security SAS
Address: F-38926 Crolles Cedex - France
Product type: Contact detector
Trade mark: Daitem
We declare under our sole responsibility that the product to which this
declaration relates is compliant with the essential requirements of the
following directives:
• R&TTE Directive: 99/5/EEC
• Low voltage directive: 2006/95/EC
• Directive ROHS: 2002/95/EC
in compliance with the following harmonised European standards:
Products code
EN 300 220-2 V2.3.1
EN 55022 & 55024 (2002)
EN 50130-4 (95) + A1 (98) + A2 (2002)
EN 60950 (2006)
EN 301 489-1 V1.8.1
This product can be used in all EU, EEA Countries and Switzerland.
Crolles, 02.01.2013
Signature: Patrick Bernard