Keypad Enrollment

Enter keypad programming by pressing [,][8][Installer's Code][000].
[0] Partition / Slot Assignment
Digit
Option
1st
Partition Assignment (0=Global Keypad)
2nd
Slot Assignment
[1]-[5] Function Key Assignment
Function Key
Button Valid Range Default
[1] Function Key 1 Assignment
[2] Function Key 2 Assignment
[3] Function Key 3 Assignment
[4] Function Key 4 Assignment
[5] Function Key 5 Assignment
Keypad Function Keys
Please see your system installation manual for a complete list of all the function key options available for
your system.
[00] - Null
[08] - Bypass Mode
[01] - Partition 1 Select [09] - Trouble Display
[02] - Partition 2 Select [10] - Alarm Memory
[03] - Stay Arm
[11] - User Programming [22] - Activate Camera
[04] - Away Arm
[12] - User Functions
[05] - No Entry Arm
[13] - Command Output 1 [24] - Bypass Group Recall
[06] - Chime On/Off
[14] - Command Output 2 [26] - Time & Date Program
[07] - System Test
[16] - Quick Exit

Keypad Programming

Enter keypad programming by pressing [,][8][Installer Code][,]
[001]-[064] Zone Label 1 to 64
(PK5500\RFK5500 Only)
ex. For Zone 1 enter section [001], for Zone 2 enter section [002] etc. Default: "Zone 1" - "Zone 64"
Section
Zone
I _ ____I _ ____ I _ ____I _ ____I _ _ ___I _ ____I _ __ __I _ ____I _ ____ I _ ____I _ ____I _ _ ___I _ ____I _ ___ _I
[001] to [064] 1 to 64
I _ ____I _ ____ I _ ____I _ ____I _ _ ___I _ ____I _ __ __I _ ____I _ ____ I _ ____I _ ____I _ _ ___I _ ____I _ ___ _I
Valid Range
Default
0 to 8
1
1 to 8
LED,ICON=1/LCD=8 I_____I
Function
00 to 32
03
Stay Arm
00 to 32
04
Away Arm
00 to 32
06
Chime On/Off
00 to 32
14
Command Output 2 I_____I_____I
00 to 32
16
Quick Exit
[17] - Activate Stay/Away [28] - Partition 4 Select
[19] - Command Output 3 [29] - Partition 5 Select
[21] - Command Output 4 [30] - Partition 6 Select
[31] - Partition 7 Select
[23] - Bypass Recall
[32] - Partition 8 Select
[27] - Partition 3 Select
Label
[065] Fire Alarm Label (28 Characters)
Default:"Fire Zone"
I _ ____I _ __ __I _ ____I _ ___ _I _ ____I _ ____I _ _ ___I _ ____I _ __ __I _ ____I _ ____ I _ ____I _ ____I _ _ ___I
[065]
I _ ____I _ __ __I _ ____I _ ___ _I _ ____I _ ____I _ _ ___I _ ____I _ __ __I _ ____I _ ____ I _ ____I _ ____I _ _ ___I
[066] Fail to Arm Event Message
I_____I
Default: "System Has Failed to Arm"
I _ ____I _ ____I _ __ __I _ ____I _ ___ _I _ ____I _ ____I _ ____I _ ____I _ __ __I _ ____I _ ____ I _ ____I _ ____I _ _ ___I _ ____I
[066]
I _ ____I _ ____I _ __ __I _ ____I _ ___ _I _ ____I _ ____I _ ____I _ ____I _ __ __I _ ____I _ ____ I _ ____I _ ____I _ _ ___I _ ____I
[067] Alarm When Armed Event Message
I_____I_____I
Default: "Alarm Occurred While Armed < >"
I _ ____I _ ____ I _ ____I _ ____I _ _ ___I _ ____I _ ___ _I _ ____I _ ____I _ ____I _ ____I _ __ __I _ ____I _ ___ _I _ ____I _ ____I
I_____I_____I
[067]
I _ ____I _ ____ I _ ____I _ ____I _ _ ___I _ ____I _ ___ _I _ ____I _ ____I _ ____I _ ____I _ __ __I _ ____I _ ___ _I _ ____I _ ____I
I_____I_____I
[071] First User Display Mask
Default
Option
ON
I____I
I_____I_____I
ON
I____I
ON
I____I
ON
I____I
OFF I____I
OFF I____I
OFF I____I
OFF I____I
[072] Second User Display Mask
Default
Option
ON
I____I
OFF I____I
OFF I____I
ON
I____I
ON
I____I
OFF I____I
OFF I____I
OFF I____I
[073] Download LCD Message Duration
Default: 003 I_____I_____I_____I (Valid entries are 000-255), 000=Unlimited Message Disp.
This number represents the number of times the Downloaded message is cleared by pressing any key while
the message is up after timeout).
(PK5500\RFK5500 Only)
(PK5500\RFK5500 Only)
(PK5500\RFK5500 Only)
ON
1
Hold [P]anic Key prompt ON
2
Auto-arm Control/Time prompt ON
3
Quick Arm prompt ON
4
Interior Arm prompt ON
5
Quick Exit prompt ON
6
Thermostat Control prompt ON
7
ACK All Trouble Prompt ON
8
Music Input prompt ON
ON
1
User-initiated Call-up prompt ON
2
For Future Use
3
Walk Test prompt ON
4
Command Output#1 prompt ON
5
Command Output#2 prompt ON
6
Command Output#3 prompt ON
7
Command Output#4 prompt ON
8
For Future Use
(PK5500\RFK5500 Only)
OFF
Hold [P]anic Key prompt OFF
Auto-arm Control/Time prompt OFF
Quick Arm prompt OFF
Interior Arm prompt OFF
Quick Exit prompt OFF
Thermostat Control prompt OFF
ACK All Trouble Prompt OFF
Music Input prompt OFF
OFF
User-initiated Call-up prompt OFF
Walk Test prompt OFF
Command Output#1 prompt OFF
Command Output#2 prompt OFF
Command Output#3 prompt OFF
Command Output#4 prompt OFF