SETTING - UP THE DETECTOR
PIR SENSITIVITY ADJUSTMENT: Switch 3 of DIP-4. Use for Setting "PULSE" - provides sensitivity control of PIR according to the environment.
Position Left - "On"- High sensitivity For stable environments. Position Right - "OFF"- Low sensitivity For harsh environments.
"PIR CAL" POTENTIOMETER ADJUSTMENT: According to protected area range. Use the potentiometer marked "PIR CAL" to adjust the detection
sensitivity between 15% and 100% according to walk test in the protected area. (Factory setting is 57%). Rotate the potentiometer clockwise to increase
range, counter-clockwise to decrease range. Always walk test and re-adjust if required.
LED INDICATION OF ALARM SIGNAL: Switch 1 of DIP-4. Use for Setting "LED" - provides control of Alarm signal LED indication.
Position Left - "On" - LED enable. Position Right "OFF" - LED disable.
SOUND SENSITIVITY ADJUSTMENT: Switch 2 of DIP-4. Use for Setting "AUDIO" - provides control of sound detection sensitivity. Position Left -
"On" - reducing the sensitivity of sound detection by 50%. (Use in small room). Position Right "OFF" - Sensitivity of sound detection 100%.
PET IMMUNITY SETTING: Switch 4 of DIP-4. Use for Setting "PET" 15kg - 25kg. Position Left "ON" Immunity to PET up to 15 kg.
Position Right "OFF" Immunity to PET up to 25 kg
TEST PROCEDURES
Wait for one minute warm up time after applying 12-Vdc power. Conduct testing with the protected area cleared of all people. Make sure to test the unit
thoroughly for proper detection.
Walk test: 1. Remove front cover.
across the detection area. 4. Observe that the red led lights whenever motion is detected. 5. Allow 5 sec. between each test for the detector to stabilize.
6. After the walk test is completed, you can set the "LED" to "OFF" position.
NOTE: Walk tests shoul d be conducted, at least onc e a year, to confirm proper oper ation and coverage of the detector.
ADJUSTMENT
Shock / Glass Adjustment Use only during testing and setting
NORMAL
SHOCK - for adjustment of the
frequency sensitivity with
GL ASS
SHOCK
potentiometer "SHOCK"
TEST
TEST
Glass Break adjustment
To adjust the glass break sensitivity, place the jumper accordingly GLASS TEST marking. Green (SHOCK)
LED is constantly ON. Now you can adjust the sensitivity by rotating the GLASS CAL potentiometer. Operate
the Sound Break Simulator* near the protected window and rotate the potentiometer GLASS CAL clock-
wise to increase sensitivity, and counter-clock-wise to decrease sensitivity until the Yellow and Red LEDs
are illuminating for each glass break sound.
Note: When the jumper is set for GLASS adjustment, only the high frequency sound of breaking glass is
detected. *It is r ecommended to use GLASS-BREAK Simulator FG-701 (CROW p/n 004001)
Shock Adjustment
To adjust the shock setting (increase/decrease sensitivity) place the jumper accordingly SHOCK TEST
marking - Yellow (GLASS) LED is constantly ON. Now you can adjust the sensitivity by rotating the potentiometer
SHOCK CAL. Hit gently on the protected glass and rotate the potentiometer clock-wise to increase sensitivity,
and counter-clock-wise to decrease sensitivity until the Green and Red LEDs are illuminating for each hit.
Note: When the jumper is set for SHOCK adjustment, only the low frequency of the shock signal prior to
glass breakage is detected.
SHOCK/GLASS TEST PROCEDURE
Final Testing
* Make sure to set jumper "GLASS/SHOCK" in position NORMAL. When the jumper is in this position, the
detector will detect both shock and sound frequencies. * To ensure maximum protection against false alarms,
activate any device in the area, which might automatically cycle pumps, gene
TECHNICAL SPECIFICATION
Detection Method
Quad (Four element) PIR & electret microphone
Detection Speed
0.15 - 3.6 m/sec
Power Input
8.2 - 16 Vdc
Current Draw
Alarm PIR :16.5mA; Alarm Shock & Glass
22mA; Alarm all: 18mA
Standby: 16.5 mA
BI Directional
Temp.
Compensation
YES
Pulse Count
1, AUTO
Alarm Period
2 sec
Alarm Output
N.C 28Vdc 0.1 A with 10 Ohm series protection
resistors
Tamper Switch
N.C 28Vdc 0.1A with 10 Ohm series protection
resistor - open when cover is remove
LIMITED WARRANTY: Digital Security Controls Ltd, warrants that for a period of 12 months from the date of purchase, the product shall be free of defects in materials and workmanship under normal use and that in fulfillment of any
breach of such warranty. Digital Security Controls Ltd shall, at its option, repair or replace the defective equipment upon returns of the equipment to its repair depot. This warranty applies only to defects in parts and workmanship and not to
damage incurred in shipping or handling, or damage due to causes beyond the control of Digital Security Controls Ltd, such as lightning, excessive voltage mechanical shock, water damage, or damage arising out of abuse, alteration or
improper application of the equipment.
The foregoing warranty shall apply only to the original buyer, and is and shall be in lieu of any and all other warranties, whether expressed or implied and of all other obligations or liabilities on the part of Digital Security Controls Ltd. Digital
Security Controls Ltd neither assumes responsibility for, nor authorizes any other person purporting to act on its behalf to modify or to change this warranty, nor to assume for it any other warranty or liability concerning this product.
In no event shall Digital Security Controls Ltd be liable for any direct, indirect or consequential damages, loss of anticipated profits, loss of time or any other losses incurred by the buyer in connection with the purchase, installation or operation
or failure of this product.
Motion detectors can only detect motion within the designated areas as Shown in their respective installation instructions. They cannot discriminate between intruders and intended occupants. Motion detectors do not provide volumetric area
protection. They have multiple beams of detection and motion can only be detected in unobstructed areas covered by these beams. They cannot detect motion which occurs behind walls, ceilings, floor, closed doors, glass partitions, glass
doors or windows. Any
type of tampering whether intentional or unintentional such as masking , painting, or spraying of any material on the lenses, mirrors, windows or any other part of the detection system will impair its proper operation.
Passive infrared motion detectors operate by sensing changes in temperature. However their effectiveness can be reduced when the ambient temperature rises near or above body temperature or if there are intentional or unintentional sources
of heat in or near the detection area. Some of these heat sources could be heaters, radiators, stoves, barbeques, fireplaces, sunlight, steam vents, lighting and so on.
WARNING: Digital Security Controls Ltd, recommends that the entire system be completely tested on a regular basis. However, despite frequent testing, and d ue to, but not limited to, criminal tampering or electrical disruption,
it is possible for this product to fail to perform as expected.
Imp o rtan t info rmatio n: Ch ang es o r mo di fi cation s n ot exp ressl y ap pro ved by D igi ta l Secu rity Co ntrol s Ltd cou ld voi d th e use r's au th ori ty to op erate thi s eq uip men t.
2005 Digital Security Controls Ltd
Toronto, Canada
www.dsc.com
Set "PULSE" to "ON" position, and set "LED" to "ON" position. 2. Replace the front cover. 3. Start walking slowly
NO RMAL
GL ASS
TEST
GLASS - for adjustment of
the high frequency sensitivity
SHOCK
with potentiometer "GLASS"
TEST
Warm Up Period
60 sec
RFI Protection
30V/m 10 - 1000MHz
EMI Protection
50,000V of electrical interference from lighting
Visible Light
Protection
st able ag ain st halogen light 2.4m (8ft)or reflec ted ligh t
Detection range
Glass up to 10m (90
LEDs indicator
Yellow LED (GLASS) - glass break signal for testing & adjustment
Green LED (SHOCK) - shock signal for testing & adjustment
Red LED (ALARM) - alarm signal:
Fleshing light - glass & break detection or glass & shock & PIR
detection
Constant light - PIR detection
Dimensions
118mm x 62.5mm x 41mm (4.65" x2.46" x1.61")
Weight
110 gr.
NORMAL
NORMAL -
for regular
GL ASS
SHOCK
operation
TEST
TEST
FIG 8 - PCB LAYOUT
BLOCK CONNECTOR
PYROSENSOR
SWITCH FOR
SETTINGS
0