For security reasons, your installer may prevent the bypass command from
operating on certain zones.
The "Bypass" light is ON as long as at least ONE zone is bypassed. Do not
unintentionally bypass zones when arming. Zone bypasses are automatically
canceled each time the panel is disarmed and must be re-applied before the next
arming.
TROUBLE DISPLAY
The PC1550 continuously monitors a number of
possible trouble conditions. If one of these conditions occurs, the keypad
sounder will beep quickly twice every 40 seconds and the keypad "Trouble"
indicator will light. Pressing any key on the keypad will silence the beeper but the
"Trouble" light will remain on until the trouble condition is cleared. If you cannot
determine the cause of the trouble condition, call your installer for assistance.
Press the [*] then [2] keys to display the type of trouble. The zone lights indicate
the type of trouble condition.
ZONE LIGHT TROUBLE
1.......... Defective Stand-by Battery
2.......... AC Power Failure (see Note below)
3.......... Fuse Failure
4.......... Unsuccessful Communication Attempt with Monitoring Station
5.......... Smoke Detector Circuit Trouble
6.......... Loss of Time on System Clock
Press the [#] key to return to Ready.
Note: The keypad buzzer will not sound for AC failure until there is also a low
battery condition. The "Trouble" light will come ON as soon as AC fails and will
remain on until AC restores.
SMOKE DETECTOR AND FIRE ALARM RESET
If the Fire Alarm
sounds at night, do not Investigate the alarm: follow your evacuation plan
immediately. Go to a neighbor and call the fire department.
When a Fire Alarm is generated, the bell or siren will sound with a pulsing tone.
Transmission of the fire alarm to your monitoring station is delayed for 30
seconds to allow you to cancel possible false alarms. To silence the alarm, press
the [#] Key. When the [#] Key is pressed, the system will delay transmission of
the fire alarm for an additional 90 seconds. The 90-second delay is intended to
allow you to reset the smoke detectors after a false alarm.
It the smoke detector is reset and remains reset after the 90-second delay, a fire
alarm will not be transmitted to the monitoring station.