Transducer Instruction Manual
Range:
Advance
Type:
ACDF – 3
Revision:
V1.0
2.2

Installation Precautions

To ensure proper installation and operation of the tension system, the following steps should be
performed in sequence - always install, orientate and firmly bolt down the transducer BEFORE installing
the tension sensing roller.
Welding. Unplug the cable connector from the transducer before any electric welding is undertaken on
the machine.
Transport. It is recommended that the tension sensing roller is removed from the transducer before the
machine is transported to prevent excessive shock being transmitted through to the transducer.
Failure to carry out these precautions could seriously damage the transducer and invalidate the warranty.
2.3

Mounting Surface Preparation

Precision machined surfaces are necessary as the transducer is located in the machine frame by the
close tolerance mounting spigot. The close concentricity of this mounting spigot to the bearing diameter
allows parallel path rollers and thus avoids web tracking problems. No appreciable force should be
transmitted through the four fixing bolts. See the Transducer Dimensions drawing for full details.
2.4

Bearing Lubrication

The bearing normally fitted by CMC Controls is without seals and has only the bearing manufacturers
preservative. The bearing will require lubrication by the user prior to use according to the service and
environment. When the transducer is for use in vacuum the bearing will need to be removed from the
transducer, degreased and suitably lubricated by the user before refitting into the transducer. To lubricate
the bearing remove side plate "A" only. Periodic inspection of the lubricant is advised in all cases.
2.5

Sensing Roller Balance

The tension sensing roller should be dynamically balanced when the roller speed exceeds 300 RPM as
excessive vibration can damage the transducer. Any out of balance force should not exceed 10% of the
maximum working force (MWF) of the transducer. The sensing roller must not be driven or have any force
applied to it except by the web. Even with a balanced roller, a vibration can be set up at the critical roller
speed. To ensure that this problem is avoided, the critical roller speed should be at least 20% above that
attained at maximum web speed. Consult the roller manufacturer for advice.
_____________________________________________________________________________________________________________________
Absolute Measurement Ltd. (T/A CMC Controls)
t: (0) 1732 763278
| e:
Unit 19
| Silver Birches Business Park | Aston Road | Bromsgrove | B60 3EU
| w: absolutemeasurement.co.uk