DSC LE4020 Manual de instalación - Página 2

Navegue en línea o descargue pdf Manual de instalación para Teléfono móvil DSC LE4020. DSC LE4020 8 páginas. Lte / 3g cellular alarm communicator

Safety Information

IMPORTANT
The equipment is fixed, wall-mounted and shall be installed in the position specified in these instructions
(see Figure 1: Parts). The equipment enclosure must be fully assembled and closed, with all the necessary
screws/tabs and secured to a wall before operation. Internal wiring must be routed in a manner that prevents:
- Excessive strain on wire and on terminal connections
- Loosening of terminal; connections
- Damage of conductor insulation
WARNING: Never install this equipment during a lightning storm!
Instruct the end-user to:
- Not attempt to service this product. Opening or removing covers may expose the user to dangerous
voltages or other risks. Any servicing shall be referred to trained service persons only.
- Use authorized accessories only with this equipment.
Do not dispose of the battery in fire or water. Disposing of the battery in a fire will cause rupture and
explosion.
Do not dispose of the waste battery as unsorted municipal waste. Consult your local regulations and /or
laws regarding recycling with regard to this lead-acid battery. Doing so will help protect the environment.
Some of the materials that are found within the battery could become toxic if not disposed of properly and
may affect the environment.
This equipment, LE4020/LE4020CF, is fixed and shall be installed by Service Persons only (Service Person
is defined as a person having the appropriate technical training and experience necessary to be aware of haz-
ards to which that person may be exposed in performing a task, and of measures available to minimize the
risks to that person or other persons). It shall be installed and used within an environment that provides the
pollution degree max 2, over voltages category II, in non-hazardous, indoor locations only. This manual
shall be used with the Installation Manual of the relevant alarm control panel. All instructions specified
within that manual must be observed.
The performance of the LE4020/LE4020CF depends greatly on cellular network coverage. Therefore, it
should not be mounted without first performing placement tests to determine the best location for reception
(minimum of one green LED ON). Optional antenna kits – LTE-8ANT, LTE-15ANT, LTE-25ANT, LTE-
50ANT (8ft/2.4m, 15ft/4.6m, 25ft/7.6m or 50ft/15.2m) – are available.
Approvals Information
NOTICE TO USERS, INSTALLERS, AUTHORITIES HAVING JURISDICTION AND OTHER
INVOLVED PARTIES
This product incorporates field-programmable software. In order for the product to comply with the require-
ments in the Standard for Control Units and Accessories for Fire Alarm Systems, UL 864, certain pro-
gramming features or options must be limited to the specific values or not used at all as indicated below.
Program Feature or
Option
Supervision
Inputs/Outputs
SMS Remote Control
NOTE: This product has been tested in accordance with UL 864 9th edition. According to this edition of
the standard, the supervision window for reporting single-technology communicator trouble shall be set to
five minutes. However, the product can be installed in accordance with the requirements of NFPA72 2013
edition, which allows for a 60-minute supervision window.
NOTE: Encryption shall be enabled for active communications.
Notes for using Private, Corporate and High Speed Data Networks:Network access and domain access
policies shall be set to restrict unauthorized network access, and "spoofing" or "denial of service" attacks.
Select the internet service providers that have redundant servers/systems, back-up power, routers with fire-
walls enabled and methods to identify and protect against "denial of service" attacks (i.e., "spoofing"). For
UL Residential Fire and Burglary installations, the 3G4010/LE4010 is listed as a sole means of com-
munication or as a back up when used in conjunction with a POTS line (dialer).
For ULC Residential Fire and Burglary installations, the 3G4010/LE4010 is listed as a sole means of
communication or as a back up when used in conjunction with a POTS line (dialer).
Permitted in UL 864
(Y/N?)
Yes
Yes
No
Possible
Settings
5 minutes /60
minutes
Fire/Burg signals
Enable/Disable
2
Settings Permitted in
UL 864
5 minutes (see note below)
Fire related signals only
Disable