Installing Ethernet Communicator in Panel
a. Disconnect both AC power and battery connections from the panel, and disconnect tele-
phone line.
Figure 3:Communicator Wiring Diagram
Input Ratings:
+10.8V ~ +12.5 VDC
100mA
DSC Panel min. power requirements:
- 16.5 VAC 40 VA transformer;
- 12 VDC 7Ah battery
HS2016/2032/2064/2128
AC AC
4. Install the RS-422 connections (R models only). If using the communicator with a 3rd party
device, wire the connections as per the table below:
NOTE: The GND connection is optional. DSC recommends connecting GND wire at both ends.
Install Network Cable
1. Route the CAT 5 Ethernet cable through back of the panel and plug it into the communicator's
RJ45 jack.
2. Perform the following steps for initial power on of the panel with communicator installed:
a. Reconnect the AC power, telephone line, and battery + connector to the panel.
(The communicator and panel will power up together).
b. Observe that the communicator's red and yellow LEDs are flashing together while it initial-
izes. The red and yellow LEDs will continue to flash until the communicator has success-
fully communicated to all programmed receivers. If this is the first time the communicator
has been powered up, the module will not be able to initiate communication until it has been
programmed.
NOTE: Initialization may take several minutes to complete. Red and yellow LEDs will flash
together during initialization. Do not continue to next step until the red and yellow LEDs
have stopped flashing. (If only the yellow LED is flashing, there is a communicator trou-
ble). Correct trouble indicated by flashes on yellow LED before continuing. (for trouble-
shooting assistance see Table 6 ).
3. Mount the panel in location.
UA621
RS-422
To 3rd party device
AUX+
PGM1
PGM3
Z1 COM Z2 Z3 COM Z4 Z5 COM
PGM2
PGM4
Table 3: RS-422 Connections
3rd Party Device
TX+
TX-
RX+
RX-
GND (Optional)
Internet Alarm Communicator Installation Guide
TL280(R)
DSC
UA601
PC-LINK
PCLINK_2
Red
Z6 Z7 COM Z8
RING
TIP
T-1
Communicator
RX+
RX-
TX+
TX-
GND
4
1
AUDIO/DEFAULT
Jumper pins 4 and 5
to reset.
Network Link
YELLOW
RJ-45
COM
From NID
TL2803G(R)
Red
Use only CAT5
Supervised
Maximum cable length
100 m (328 ft)
R-1