DSC Power Series Manual de instalación - Página 2

Navegue en línea o descargue pdf Manual de instalación para Pantalla táctil DSC Power Series. DSC Power Series 14 páginas. Neo image sensor
También para DSC Power Series: Manual de referencia (2 páginas), Manual (18 páginas), Manual de consulta rápida (2 páginas), Instrucciones de instalación (2 páginas), Manual rápido (4 páginas), Manual de instrucciones de instalación (11 páginas)

DSC Power Series Manual de instalación
• Batteries: Refer to the Batteries section for details
• Operating Temperature Range: 60° to 80°F
• Weight: 3.1 oz. (with batteries and without mounting accessories)
• Dimensions: 3.1'' h x 1.8'' w x 2.3'' d
• Supervisory Interval: 100 minutes (sensor), 3 hours (alarm hardwire)
• Wireless Signal Range: Greater than 400 ft open air
• Color: White
• Recommended Mounting Height and Angle: Refer to the Recommended Install Height and Angle Table
• Motion Profiles & Sensor Range: Refer to the PIR Sensitivity Settings Table
HARDWARE COMPATIBILITY REQUIREMENTS – By Panel
Panel
Impassa
PowerSeries Neo

OTHER FEATURE COMPATIBILITY

Two-Way Voice Compatibility - Images cannot be transmitted while a Two-Way Voice call is in session. When the
Image Sensor is installed on a system with Two-Way Voice over the cellular network, image transmission during an
alarm may be interrupted by the two-way session. The image transmission resumes once the call has terminated.

PET IMMUNITY SETTINGS

Two parts to making the Image Sensor pet immune:
1. Set PIR sensitivity settings to "low",
2. Mount set at a height of 6 ft, and install the sensor with the 6 degree mounting angle.
BATTERIES
Battery type: The Image Sensor uses 2 AA 1.5v Energizer Ultimate Lithium batteries (UL compliant).
Expected Battery Life: Approximately 4 years with lithium batteries.
Voltage Thresholds: With lithium batteries, low battery alerts are issued at 3.05V. The sensor cannot operate when the
voltage reads below 2.30V.
Low Battery Notification: Panel will display a low battery alert for the sensor and/or notifications are issued via the
Alarm.com platform if the customer has subscribed to this notification type.
https://answers.alarm.com/Installation_and_Troubleshooting/Image_Sensor/DSC_PowerSeries_Neo_Image_Sensor/DSC_PowerSeries_
Panel Version
V1.3+
V1.0+
Module Firmware
Alarm.com SKU
Alarm.com SKU
Extra Hardware
3G8055(I) or CD8055(I)
SKU 3G8080(I) or
CD8080(I)
Updated: Tue, 17 Apr 2018 13:46:31 GMT
2