OUTPUT SOURCE LIST
0
Not used
1
RESERVED
3
2
Arm safety on alarms
3
Audible alarm
4
Battery over volts warning
5
Battery under volts warning
6
Can ECU data fail
7
Can ECU error
8
Can ECU fail
9
Can ECU power
10
Can ECU stop
11
Charge alternator shutdown
12
Charge alternator warning
13
Close gen output
14
Close gen output pulse
15
Close mains output
16
Close mains output pulse
17
Combined mains failure
18
Common alarm
19
Common electrical trip
20
Common shutdown
21
Common warning
22
RESERVED
23
RESERVED
24
RESERVED
25
RESERVED
26
RESERVED
27
RESERVED
28
RESERVED
29
Emergency stop
30
Energise to stop
31
RESERVED
32
RESERVED
33
Fuel relay
34
Gas choke on
35
Gas ignition
36
Generator available
37
Generator over voltage shutdown
38
RESERVED
39
RESERVED
40
Loss of magnetic pickup signal
41
Low fuel level
42
RESERVED
43
RESERVED
44
RESERVED
45
RESERVED
46
RESERVED
47
Open gen output
48
Open gen output pulse
49
Open mains output
50
Open mains output pulse
51
RESERVED
52
RESERVED
53
Preheat during preheat timer
54
Preheat until end of crank
55
Preheat until end of safety timer
56
Preheat until end of warming timer
57
Smoke limiting
58
Start relay
59
RESERVED
60
RESERVED
61
Waiting for manual restore
62
Flexible sender High Shutdown
63
Flexible sender High Warning
64
Flexible sender Low Warning
65
Flexible sender Low Shutdown
44xx – 02 (CAN option) only
44xx – 01 (Magnetic pickup option) only
TYPICAL WIRING DIAGRAM
DSE4420
D E E P S E A E L E C T R O N I C S
DSE4420 INSTALLATION INSTRUCTIONS
This instruction sheet is for DSE4420 MKII controllers only.
For DSE4420 controllers below version 2 use DSE publication
053-056
ACCESSING THE FRONT PANEL CONFIGURATION EDITOR
Ensure the engine is at rest and the module is in stop mode by
pressing the stop/reset
button.
Press the stop/reset
and down
buttons simultaneously.
The configuration icon
is displayed, along with the first
configurable parameter.
EDITING A PARAMETER
Press
to select the required 'page' as detailed in the
configuration tables.
Press
(+) to select the next parameter or
previous parameter within the current page.
When viewing the parameter to be changed, press the
The value begins to flash.
Press
(+) or
(-) to adjust the value to the required setting.
Press
the save the current value, the value ceases flashing.
Press and hold the
button to exit the editor, the configuration
icon
will be removed from the display.
NOTE: - pressing and holding the + / - buttons will give auto-
repeat functionality. Large values can be changed quicker by holding
the buttons for a prolonged period. For instance large timers
increment in 1 second steps to 1 minute, then in 30 second steps to
1 hour, then in 30 minute steps.
DIMENSIONS AND MOUNTING
For flat surface mounting in a Type 1 enclosure to meet UL
requirements.
DIMENSIONS
PANEL CUTOUT
180mm x 116mm x 42mm
154mm x 98mm
(7.1" x 4.6" x 1.7")
(6" x 3.9")
Deep Sea Electronics Plc.
Deep Sea Electronics inc.
Tel:+44 (0)1723 890099
Phone: +1 (815) 316-8706
Fax: +44 (0)1723 893303
Fax: +1 (815) 316- 8708
TOLL FREE (USA only) :
Web: www.deepseaplc.com
Tel: 1 866 636 9703
Web: www.deepseausa.com
053-079 ISS 5
(-) to select the
button.