6. General
Temperature: 0 to 60°C (32 to 140°F)
Pressure: Max. 6.0 bar (85 psi)
Weight: 140 g (5.38 oz)
Accuracy : +/- 5%
Connection: 1/2" BSP
Materials
Sensor Body: Glass Filled PPS
Turbine: PA composite Turbine holder Acetal Copolymer, TICONA M90
Turbine Shaft: Ceramic
O-Ring: EPDM Rubber
Control Unit Housing: ABS resin
7.0 Operation Guide
7.1 Install Batteries
Slide off the cover of the battery compartment and insert two (2) AA batteries.
Then slide the cover back.
7.2 Connecting Fitting
ATS-FM-44 connectors are 1/2" BSP.
7.3 Operating
T he ATS-FM-44 will automatically turn on when there is water flowing through the sensor.
It will automatically turn off after 10 seconds when there is no water flowing.
7.4 Display and Mode Selection
Press the "DISPLAY" button to turn on the Flow Meter LCD screen. Press the
"DISPLAY" button again to display the accumulated flow volume (flow totalization)
or real-time flow rate.
7.5 Reset
Press and hold the "RESET" button for four (4) seconds, to reset the total measured
volume to zero (0).
7.6 Low Battery Power Alert
When battery power is lower than normal working level, a buzzer will beep twice and
the battery symbol on the screen will blink to notify users to change the battery. Once
the batteries are replaced, the alert will be turned off. Data will be stored in memory and
restored when the user replaces the batteries.