CN203 (40 pin connector) PN FCI 10106813-041112LF
1 thru 6
Negative rail power supply
11 thru 18
Power Ground
23 thru 30
Amplifier Output
35 thru 40
Positive rail power supply
Circuitry Protection:
The VF-150 OEM circuitry incorporates over-current, over-temperature, and short-circuit
protection. There are two operating modes for the current limit protection circuitry:
1. Auto mode
a. In this mode the amplifier will monitor the output current and make decision
based on the current and time.
b. If the output current is above 150mA or below -150mA for more then 10msec the
amplifier will limit the output current to ±150mA until the output current is less
then 50mA for 30msec.
2. 150mA mode
a. This mode will configure the amplifier so that only a maximum of 150mA is
available at the output.
The over temperature protection will turn off the amplifier and disconnect from the power supply
when the temperature reaches 80C. The amplifier will be re-enabled when the temperature drops
to 70C. To enable the amplifier the temperature must be below 70C.
Short circuit protection is activated when the output is above 75mA for more then one second.
Under this condition the amplifier will be disconnected from the power supply for one second.
After one second the amplifier will be reconnected.
Recommended Environmental Conditions for Operation:
The VF-150 is designed to operate in non-hazardous environments. Any deviation from the
specified environment must be approved by DSM and may result in the voiding of any warranty.
Any deviation not approved by DSM will be grounds for voiding of any warranty.
• Environmental Temperature:
• Percent Relative Humidity:
• Operating Supply Voltage:
• Maximum Difference Between Rail Voltages:
• Positive Rail:
• Negative Rail:
0-50C
0-80% non condensing
5 VDC input @ 1A
250 VDC
130VDC to 210 VDC
-15VDC to -110 VDC
Hardware Version V131028
114 Southeast Parkway Ct.
Ste 160
Franklin, TN 37064
Tel: 615/595-6665
Fax: 615/595-6610