Atsumi Electric NR60TD Manual de instrucciones de instalación - Página 7
Navegue en línea o descargue pdf Manual de instrucciones de instalación para Sensores de seguridad Atsumi Electric NR60TD. Atsumi Electric NR60TD 8 páginas. Beam detectors
10
OPERATION CHECK
1. Alarm Operation
To check the alarm operation, actually walk along as-
sumed intrusion path near the transmitter and receiver,
respectively and in-between as shown in the figure be-
low.
Check that the alarm LED lights up and the controller
receives the alarm signal when the beam is interrupted.
11
TROUBLESHOOTING
Problem
False alarm is output fre-
quently.
No alarm is output even when
beam is interrupted.
<Note>
If the trouble remains unsolved even after taking above solution, please consult the dealer of your purchase.
12
DIMENSIONS
Possible cause
An obstacle exists between transmitter and receiver.
Optical axis alignment is incomplete.
Installation condition is unstable.
Distance between transmitter and receiver exceeds
rated distance.
Beam is interfered with beam from another detector.
There is an electrical noise source in nearby area.
Sunlight enters receiver within ±3° angle.
There is a highly reflective wall in parallel with beam.
Reflectance of floor surface is high.
Beam is interfered with beam from another detector.
Height of installation position is inappropriate.
77
24
Knockout
Transmitter
2. Tamper Operation
Check that the controller receives an abnormal signal
when either of the transmitter and receiver cover is open.
Remove obstacle.
Perform optical axis alignment again to obtain 3V or
more tester level.
Stabilize installation condition.
Change installation position or use other detector with
suitable rated distance.
Take proper measure to avoid beam interference.
Change installation position.
Replace transmitter and receiver.
Adjust optical axis so that it is on the other side of
reflection surface.
Adjust optical axis so that it is on the other side of
reflection surface.
Take proper measure to avoid beam interference.
Change installation position to a proper height.
147
117
83
Center of the
Upper Beam
Center of the
Lower Beam
7
Solution
Mount plate
Mount bracket
✽ This unit can be installed
to a pole with ø38.0 to
ø42.7 diameter.
ø42.7
✽
Receiver