DSPPA DA8250 Manual del usuario - Página 9
Navegue en línea o descargue pdf Manual del usuario para Amplificador DSPPA DA8250. DSPPA DA8250 15 páginas. Public address system m/s amplifier
*
3. Setup Instructions
3.1 Main interface operation instructions
Operating parameters (Each column corresponds to the real-time display of a channel's operating parameters):
Temperature (%):The temperature inside the main amplifier of each channel.
Volume (%):Volume of each channel, range:0~100.
Power (W):Power of each channel
Status: The current state of each channel: self-test, normal, fault, power halved, overheated, turn off.
1. Self-inspection:Self-inspection at boot time
2. Normal:The channel's amplifier is in normal playback.
3. Fault: There are sub-faults, power amplifier faults, and line faults. If the channel amplifier is broken
and no standby power amplifier can be called, no signal will be output.
4. Overheat:When internal temperature of the main power amplifier of this channel detects 76° C, it
shows "overheat protection" and automatically switches to standby power amplifier; when
the temperature drops to 70° C, it will automatically switch to the main power amplifier of
the original channel. There is no channel installed amplifier, the corresponding column does
not show the operating parameters.
5. Turn off:The channel's power is turned off. Eight main amplifiers and one spare amplifier can be
Boot interface
(normal display)
Main interface
5
M/S Amplifier