START AND PUTTING WATER STORAGE TANK TO OPERATION
 Open the gas valve before the appliance.
 Turn the control button of the gas fitting anticlockwise to the position of ignition burner („ "
pilot).
 Press the control burner to stop and light the ignition burner by pressing the piezoelectric
lighter. It is necessary to keep the control button pressed for 10–15 seconds (pict. No.1).
 Release the control button and make sure whether flame of the ignition burner keeps on
burning. If not, repeat the procedure again.
 Set up the temperature required by the control button of the regulation thermostat.

Regulation of water temperature

By a regulation button, switch-off temperature can be set up in the range of 40-70°C. We
recommend to set the regulation button to 4-5 position. In this position we can reach the
temperature of 55-60°C. For this temperature only minimum of incrustation is created. For fast
heating of water in the tank it is possible to set up the button to level 7. At this level the
incrustation is higher, so it is recommended only oaboutsionally. If flame of ignition burner is
burning, thermal insulation of the heater enables keeping the temperature of heated water
for a longer period without repeated ignition of the main burner.
Water temperature can be set up by the control button of the regulation thermostat like
following:
Position 1 (about 40°C);
Position 4 (about 55°C);
Position 7 (about 72°C)
SIT 630 EUROSIT GAS VALVE
Gas supply
to the main burner
Main gas supply
position 2 (about 45°C); position 3 (about 50°C);
position 5 (about 60°C); position 6 (about 66°C);
of regulation thermostat
7
Piezoelectric lighter
Control button