PROBLEM
Display shows HIGH
CHARGING VOLTS
WHEN AT IDLE.
Display shows RIPPLE
DETECTED NORMAL.
Display shows NO
RIPPLE DETECT.
Display shows RIPPLE
DETECTED HIGH.
Display shows ALT. LOAD
VOLTS HIGH.
Display shows ALT. LOAD
VOLTS LOW.
Display shows ALT. LOAD
VOLTS NORMAL.
Output Leads .............................................................................................. 2299001824
Battery Cover .............................................................................................. 3799006010
Paper Cover ................................................................................................ 3799006020
Carrying Case ............................................................................................. 2299001986
Paper Roll (1) .............................................................................................. 4999000106
Cable Cover ................................................................................................ 3799006724
Replacing The Output Leads
1. Remove the screw in the backside
bottom cover of the battery tester, and
then remove the cover.
2. Disconnect the old cable connectors
and insert the connectors of the new
cable into the corresponding same color
sockets (yellow connector into yellow
socket; red connector into red socket;
white connector into white socket; black
connector into black socket).
POSSIBLE CAUSE
The alternator output exceeds
the normal limits of a functioning
regulator.
The diodes are functioning
properly in alternator/stator.
The diodes are functioning
properly.
Diodes are bad.
The alternator output voltage
exceeds the normal limits of a
functioning regulator.
The alternator output voltage
is low.
The alternator output voltage is
normal.
REPLACEMENT PARTS
•
7
Check the manufacturer
specifications for the correct limit.
No problem is detected.
No problem is detected.
Have the alternator checked.
Have the alternator checked.
Have the alternator checked.
No problem is detected.
IMPORTANT: There is a small rib on the
tester case, place the first slot of the
rubber strain relief attached to the cable
over this rib. There is also a rib on the
cover you removed, make sure that the
rib is in the first slot of the strain relief
when you replace the cover. Replace the
cover and tighten the screw. Do not
over-tighten.
•
SOLUTION