3onedata ES209G-1GF Manual de instalación - Página 2
Navegue en línea o descargue pdf Manual de instalación para Interruptor 3onedata ES209G-1GF. 3onedata ES209G-1GF 2 páginas. Unmanaged ethernet switch
También para 3onedata ES209G-1GF: Manual de instalación (2 páginas)
Tips:
Insert a little to the bottom, lift upward and then insert
to the top.
Step 3
Check and confirm the product is firmly installed on
DIN-Rail, then mounting ends.
【Disassembling DIN-Rail】
Step 1
Device power off.
Step 2
After lift the device upward slightly, first shift out the
top of DIN-Rail mounting kit, then shift out the
bottom of DIN-Rail, disassembling ends.
Attention before power on:
Power ON operation: first connect power line to the
connection terminal of device power supply, then power
on.
Power OFF operation: first unpin the power plug, then
remove the power line, please note the operation order
above.
【Power Supply Connection】
DC power supply
The device provides 4 pins 7.62mm pitch
power supply input terminal blocks and
two
independent
systems for PWR1 and PWR2. The power
supply supports anti-reverse connection.
Power supply range: 12~48VDC
【DIP Switch Settings】
The device provides 4 pins DIP switches for
function settings, where "ON" is enable valid
terminal. Please power off and power on after
changing the status of DIP switches. DIP switches definition
as follows:
DIP
Definition
Operation
1
Flow control
Set the DIP switch to ON
-
2
Reserved
Set the DIP switch to ON, fiber
3
Port isolation
DIP
Definition
4
Reserved
【Checking LED Indicator】
The function of each LED is described in the table as below:
LED
P1/P2
Link/Act
(G1-G9)
【Specification】
Panel
Gigabit copper port
Gigabit fiber port
DC
power
supply
Indicator
Exchange attributes
Backplane bandwidth
Packet buffer size
MAC table size
Power supply
Input power supply
Access terminal
Consumption
No-load
Operation
port can communicate with
copper port. Copper ports can't
communicate with each other.
-
Status
Description
ON
P1/P2 is running normally
P1/P2 is disconnected and running
OFF
abnormally.
ON
Ethernet port connection is active.
Blinking
Data transmitted
OFF
Ethernet port connection is inactive.
10/100/1000Base-T(X), RJ45,
automatic flow control, full/half
duplex mode, MDI/MDI-X
autotunning
1000Base-X, SC interface
Power indicator, interface
indicator
20G
1Mbit
8K
24VDC (12~48VDC)
Support dual power supplies
redundancy,
reverse-connection protection
4 pins 7.62mm pitch terminal
blocks
3.9W@24VDC
Full-load
8.1W@24VDC
Working environment
Working temperature
0~55℃
Storage temperature
-10~65℃
Working humidity
5%~95% (no condensation)
Protection grade
IP30 (metal shell)