3onedata ICS5400 Series Manual de instalación rápida - Página 2

Navegue en línea o descargue pdf Manual de instalación rápida para Interruptor 3onedata ICS5400 Series. 3onedata ICS5400 Series 4 páginas. Rack-mounted layer 3 industrial ethernet switch

8.
Device indicators, from left to right in turn they are:
-
Ethernet port indicator (G1-G24/28/32/40,
X1-X4)
-
Power indicator (P2-P1)
-
Alarm indicator (ALM)
-
Running indicator (RUN)
9.
DC power supply input terminal blocks
10.
AC power 2 supply input socket (PWR2)
11.
AC power 1 input socket (PWR1)
【Mounting Dimension】
The external dimensions of this series of products are the
same, unit: mm.
DC device
AC device
Notice Before Mounting:
Don't place or install the device in area near water or
moist, keep the relative humidity of the device
surrounding between 5%~95% without condensation.
Before power on, first confirm the supported power
supply specification to avoid over-voltage damaging the
device.
The device surface temperature is high after running;
please don't directly contact to avoid scalding.
【Rack-mounted】
This product adopts 1U rack-mounting, mounting steps as
below:
Step 1
Select the device mounting location to ensure
enough size.
Step 2
Adopt 4 bolts to install the mounting lugs in the
device position as figure below.
Step 3
Place the device in the rack; adopt 4 bolts to fix two
sides mounting lugs in the rack.
Step 4
Check and confirm the product is mounted firmly on
the rack, mounting ends.
【Disassembling Device】
Step 1
Power off the device.
Step 2
Adopt screw driver to loosen the 4 bolts fixed on
the mounting lugs in the rack.
Step 3
Shift out the device from rack, disassembling ends.
Notice before power on:
Power ON operation: First insert the power supply
terminal block into the device power supply interface,
then plug the power supply plug contact and power on.
Power switch "—" means power ON, "O" means power
OFF.
Power OFF operation: First, put the powers switch to
the "O" side and then disconnect the power supply.
Finally disconnect the connector between the device and
the power cord. Please notice the operation order above.
Please be aware of the power input range supported by
the device before powering on. Use the recommended
voltage of the device to avoid device damage.
【Power Supply Connection】
DC device power supply
Model I- Model IV provide 5-pin
5.08mm pitch terminal blocks and the
built-in dual power supply redundancy
supports DC power input. The power
input supports 1 single power supply
input or 2 power supply inputs at the same time; When two
power supply input at the same time, it supports redundant
backup of power supply. If one power supply fails, the device
can still work normally without interruption. Power supply
supports anti-reverse connection, which cannot power the
device but won't damage it when it's reversely connected. The
definitions of power pin are shown in the left figure, and the
power input range is 24VDC/48VDC (12~55VDC).
AC device power supply