Celerity Fibre Channel 16Gb Adapters
The ATTO Celerity 16Gb HBAs leverage two next-
generation storage technologies: PCIe 3.0
interconnect and 16-Gigabit Fibre Channel.
With 16-Gb FC speeds of up to 1600 MB/sec. per
channel, 16Gb Celerity adapters support the most
demanding application requirements, including high-
definition video, rich content databases and other
high-bandwidth environments.
ATTO Celerity host adapters are an integrated family
of advanced storage connectivity solutions that are
designed to provide reliable connectivity, intelligence
and scalability.
164E technical specifications
• Four independent Fibre Channel ports
• 16-Gigabit data transfer rates
• 3200 MB/sec. maximum full-duplex throughput
per channel
• Supports all FC topologies: fabric, arbitrated
loop and point-to-point
• ANSI Fibre Channel: FC-FS, FC-AL, FCP, FC-
AL2, FC-PLDA, FC-FLA
• Flash ROM for easy field upgrades
• FC Class 3 support
• Local management and diagnostics
• Buffer credits: 81
• ATTO Advanced Data Streaming (ADS™)
Technology
• Length: 6.600 inches
• Height: 4.376 inches
• Operating temperature and Airflow: 0-40 ºC (32-
104 ºF) 100lfm minimum recommended;
40-55 ºC (104-132 ºF) 300lfm minimum
recommended
• Storage temperature: -40 to 70 ºC (-40 to 158 ºF)
2 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
• Relative humidity: 10 to 95% non-condensing
• RoHS compliant
162E Technical specifications
• Two independent Fibre Channel ports
• 16-Gigabit data transfer rates
• 3200 MB/sec. maximum full-duplex throughput
per channel
• Supports all FC topologies: fabric, arbitrated
loop and point-to-point
• ANSI Fibre Channel: FC-FS, FC-AL, FCP, FC-
AL2, FC-PLDA, FC-FLA
• Flash ROM for easy field upgrades
• FC Class 3 support
• Local management and diagnostics
• Buffer credits: 81
• ATTO Advanced Data Streaming (ADS™)
Technology
• Length: 6.600 inches
• Height: 2.731 inches
• Operating temperature and Airflow: 0-40 ºC (32-
104 ºF) - 60lfm minimum recommended;
40-55 ºC (104-132 ºF) 100lfm minimum
recommended
• Storage temperature: -40 to 70 ºC (-40 to 158 ºF)
• Relative humidity: 10 to 95% non-condensing
• RoHS compliant