Installation & Set Up Guide
Stage 1 –
3) Feed standard 12 core alarm cable into the cable entry; bare the wires and
connect to the removable terminal block as shown in fig. 7. Screw the unit to the
wall ensuring that the tamper pin is correctly located and that the tamper microswitch
is closed. See fig. 4 and 5. To aid installation, two spare tamper feet are provided.
One is 1mm longer and the other is 2mm longer than the tamper foot originally
fitted. The tamper foot is a push fit and can be removed by carefully pulling it from
the pin. See fig. 2.
4) Always ensure when replacing the electronics module that the LED is facing
forward so as to ensure correct alignment of the beam pattern. (Refer section
titled "Beam Alignment")
5) When the detector has been aligned to suit the installation, replace the front cover
and lock as shown.
See fig. 6.