Step 1
Check if the DIN-Rail mounting kit is installed firmly.
Step 2
Insert the bottom of DIN-Rail mounting kit (one side
with spring support) into DIN-Rail, and then insert
the top into DIN-Rail.
Tips:
Insert a little to the bottom, lift upward and then insert
to the top.
Step 3
Check and confirm the product is firmly installed on
DIN-Rail, then mounting ends.
【Disassembling DIN-Rail】
Step 1
Power off device.
Step 2
After lifting the device upward slightly, first shift out
the top of DIN-Rail mounting kit, and then shift out
the bottom of DIN-Rail, disassembling ends.
Notice before power on:
Power ON operation: First insert the power supply
terminal block into the device power supply interface,
and then plug the power supply plug contact and power
on.
Power OFF operation: First, remove the power plug,
and then remove the wiring section of terminal block.
Please pay attention to the above operation sequence.
【Power Supply Connection】
Model I
This Model I device provides 6-pin 5.08mm pitch input
terminal blocks, including 4 pins power supply terminal blocks
on the left side. It provides two
independent
systems of P1 and P2. The power
supply supports non-polarity and
anti-reverse connection, which can
ensure the normal operation of the
device
after
it's
reversely
connected.
12~48VDC.
Model I
This Model II device provides 6-pin
5.08mm pitch input terminal blocks,
including 4 pins power supply
terminal blocks on the left side. It
provides
power supply systems of P1 and P2.
The power supply supports anti-reverse connection, which
can prevent device from damage after it's reversely connected,
but it cannot be powered on. Voltage range is as below:
Voltage range without using PoE function: 12~48VDC
Rated voltage: 48VDC
Maximum voltage range: 44VDC-55VDC
【Relay Connection】
This series device provides 6-pin
5.08mm pitch input terminal blocks,
and the relay occupies the right 2
pins. Relay terminals are a set of
normally open contacts of the
device alarm relay. They are open
circuit in the state of normal non
alarm, closed when any alarm information occurs. For
example, they are closed when powered off, and send out
alarm. The switch supports 1 relay alarm information output
that can output DC power supply alarm information or network
abnormality alarm. It can be connected to alarm light or alarm
buzzer or other switching value collecting devices, which can
timely inform operators when the alarm occurs.
【DIP Switch Settings】
DC
power
supply
status of DIP switch.
DIP switches definition as follows:
DIP
Voltage
range
1
2
3
4
two
independent
DC
【Checking LED Indicator】
The device provides LED indicators to monitor the device
working
troubleshooting; the detailed status of each LED is described
in the table as below:
LED
P1
P2
ALM
RUN
Link/Act
(1-6)
Provide 4 pins DIP switch for function settings,
where "ON" is enable valid terminal. The device
needs to be powered on again to change the
Definition
Operation
Set the DIP switch to ON, the device
Restore
will root automatically and restore to
Factory
factory settings, then turn off the DIP
Settings
switch.
Reserved
-
Reserved
-
Reserved
-
status
with
a
comprehensive
Indicate
Description
P1 is connected and running
ON
normally
P1 is disconnected and running
OFF
abnormally
P2 is connected and running
ON
normally
P2 is disconnected and running
OFF
abnormally
ON
Power supply link has alarm
OFF
Power supply link have no alarm
The device is powered on or the
ON
device is abnormal.
The device is powered off or the
OFF
device is abnormal.
Blinking 1 time per second, the
Blinking
device is running well.
The
Ethernet
interface
ON
established
a
valid
simplified
has