3onedata IES7110-2GS-P Manual del usuario - Página 4

Navegue en línea o descargue pdf Manual del usuario para Interruptor 3onedata IES7110-2GS-P. 3onedata IES7110-2GS-P 5 páginas. Managed industrial ethernet switch

3onedata IES7110-2GS-P Manual del usuario
4. Power: DC dual power supply series products 12 ~ 48VDC
AC single power supply series products 100~240VAC/DC
5. Environment: working temperature: -40 75
Storage Temperature: -40 85
Relative humidity 5% 95%
DIN Rail Installation
In order to use in industrial environments expediently, the product
adopt 35mm DIN-Rail installation, the installation steps as below:
1. Examine the DIN-Rail attachment
2. Examine DIN Rail whether be firm and the position is
suitability or not.
3. Insert the top of the DIN-Rail into the slot just below the
stiff metal spring.
4. The DIN-Rail attachment unit will snap into place as shown
below.
Wiring Requirements
Cable laying need to meet the following requirements,
1. It is needed to check whether the type, quantity and
specification of cable match the requirement before cable
laying;
2. It is needed to check the cable is damaged or not, factory
records and quality assurance booklet before cable laying;
3. The required cable specification, quantity, direction and
laying position need to match construction requirements, and
cable length depends on actual position;
4. All the cable cannot have break-down and terminal in the
middle;
5. Cables should be straight in the hallways and turning;
6. Cable should be straight in the groove, and cannot beyond the
groove in case of holding back the inlet and outlet holes.
Cables should be banded and fixed when they are out of the
groove;
7. User cable should be separated from the power lines. Cables,
power lines and grounding lines cannot be overlapped and
mixed when they are in the same groove road. When cable is
too long, it cannot hold down other cable, but structure in the
middle of alignment rack;
8. Pigtail cannot be tied and swerved as less as possible.
Swerving radius cannot be too small (small swerving causes
terrible loss of link). Its banding should be moderate, not too
tight, and should be separated from other cables;
9. It should have corresponding simple signal at both sides of the
cable for maintaining.

Specification

Technology
Standard:
Support
IEEE802.3,
IEEE802.3u,
IEEE802.3z, IEEE802.1Q, IEEE802.1p, IEEE802.1D/W
Protocol: ARP, ICMP, TCP, UDP, DHCP, DNS, HTTP, Telnet,
SW-Ring, RSTP, SNMP
Flow control: IEEE802.3x flow control, back press flow control
Interface
Electric port: 10Base-T/100Base-TX/1000Base-TX auto speed
control, Half/full duplex and MDI/MDI-X auto detect
100M optic fiber port: 100Base-FX, SC/ST/FC connector
Gigabit SFP port: 1000Base-FX, SFP slot
Console port: debug serial port carry out CLI command
Alarm port: 2 bit 7.62mm terminal block,
1 channel relay alarm output
- 4 -
Exchange attribute
100M forward speed: 148810pps
1000M forward speed: 1488100pps
Transmit mode: store and forward
System exchange bandwidth: 7.6G
MAC address table: 8K
Memory: 1M
Transfer distance
Twisted cable: 100M standard CAT5/CAT5e cable
Multi-mode: 1310nm, 2Km
Single-mode: 1310nm, 20/40/60Km
1550nm, 80/100/120Km
Power supply
DC input series
Input voltage: 12~48VDC
AC input series
Input voltage: 100~240VAC/DC
Type of input: 4 bit 7.62mm pitch terminal block
Overload current protect: 4.0A (DC) or 5.0A (AC)
Support DC dual power supply redundancy and alarm input
IEEE802.3x,
Support DC input no parity, protection reverse connection
Consumption
IES7110-2GS-P (12/48VDC):
Unload consumption: 2.2W@24VDC
Full load consumption: 5.5W@24VDC
IES7110-2GS-P (220VAC):
Unload consumption: 2.7W@220VAC
Full load consumption: 5.5W@220VAC
IES7110-2GS-2F–P (12/48VDC):
Unload consumption: 5.1W@24VDC
Full load consumption: 8.0W@24VDC
IES7110-2GS-4F–P (12/48VDC):
Unload consumption: 6.1W@24VDC