SECTION E: Cleaning the barrier
If the Barrier has been in contact with flood water, thoroughly clean and dry before storage
STEP 1: EXTEND THE SIDE PANELS FULLY
1.1 Place the barrier upright against a solid surface and hold firmly
at the lifting handles
1.2 Position the Direction Switch outwards on the Ratchet Handle
(towards the user) and Jack the Ratchet Handle to extend the
Side Panels to the 'max' position
STEP 2: REMOVE THE USED SEAL
2.1 See Section F Replacing the seal, Step 1 Remove used seal
STEP 3: CLEAN THE BARRIER
Do not allow any detergent or chemical to come into contact
with the barrier
3.1 Rinse the barrier thoroughly with clean, fresh water
to remove any debris, residue etc.
3.2 Allow to air dry completely
STEP 4: REPLACE THE SEAL
4.2 Fit Replacement Seal, see Section F,
Step 2 Fitting replacement seal
4.3 Fully retract side panels using the Ratchet Handle
4.3 Continue to Section G, Storing the barrier
CAUTION/
Floodwater may be contaminated – use gloves and eye protection. Do not use
IMPORTANT
any detergents or chemicals to clean the barrier, they may damage the seal
14
780mm –1100mm
2
The Inflatable seal is critical to creating a watertight seal on the Dam Easy
2
1
The seal is attached to the Barrier at 3 quick release points;
0
2 T-Clips on either end of the seal, secured on top of each side panel of the barrier, labelled 'A'
bar
A valve in the centre of the seal, labelled 'B', attached by a Quick Release Fitting, accessible
2
1
3
from the Seal Replacement Access Panel
0
4
bar
1 replacement seal is included in the Flood Barrier Kit, labelled 'C', additional replacement seals are
available for purchase online www.dameasyfloodbarriers.com
To avoid accidentally damaging the seal;
Store the barrier in the original packaging out of direct sunlight and extremes of temperature
Always place the barrier on a smooth even surface
Do not inflate the seal unless the barrier is secure in a doorway
Do not remove the replacement seal from the packaging before use
Do not use any tools while replacing the seal
WHEN TO REPLACE THE SEAL
To guarantee a watertight seal, Dam Easy
If there is an indication that the seal is damaged and/or is not capable of sustaining the required
air pressure when correctly installed in a suitable doorway
Every 12 months, whether or not the barrier has been in use in a doorway
Immediately after use in a doorway, when the barrier has been in contact with flood water
A
B
TOP TIP: Avoid damaging the seal by always placing the barrier on a smooth,
even surface when not installed in a doorway, and store in the original packaging
SECTION F: Replacing the seal
Flood Barrier.
®
3
4
®
recommends replacing the Seal before storing the barrier;
C
780mm –1100mm