OPTION
Concealed mixer installation
1. Disconnect your water supply system.
2. Make sure the installation niche has right size. Important! Make sure to connect the hot/cold
inlet pipe correctly (If standing in front, hot water pipe connecting to the left& cold water pipe
connecting to the right). Shower output should be directed upwards.
3. Connect the main body & water supply pipe with water inlet pipe without handle and wall plate.
4. Start the water supply system with the mixer in ʺclosedʺ position and make sure that all
connections are tight.
5. Perform additional connections tightening and sealing if necessary.
6. Install wall plate and mixer handle.
Mixers care recommendations
Follow the instructions of the manufacturer of cleaners, as well as the following rules for their use:
1. Use cleaning agents when required, according to the instructions for use.
2. The dosage and duration of treatment with cleaning agents should be selected taking into
account characteristics of the product (mixers should not be exposed to cleaning agents longer
than required).
3. Regular care can prevent calcification.
4. When using aerosol cleaners, spray them onto a special cloth or sponge and never direct
directly onto plumbing equipment, since droplets of the aerosol can damage it by hitting the holes
or slots in the equipment.
5. Immediately after cleaning, wash off the chemicals with clean water in order to completely get
rid of the residues of the product.

Important notes

Any residual liquid soap, shampoo or shower gel can also cause damage. To avoid this, wash
them thoroughly with clean water. The impact of cleaning products on damaged surfaces
increases the area of damage.
Our warranty does not cover any damage resulting from improper handling.
Warning!
The following specifications of the water supply system are required for normal operation of the mixers:
1. Working interval of pressure in the water supply system is 0.5-0.6 atm (50-620 kPa).
2. Recommended pressure range in the water supply system is 2.0-5.0 atm (206-515 kPa)
3. Difference in pressure values in the hot and cold water supply network can be up to 10%.
In case of any excess values, it is recommended to provide pressure boosting/decompression
device.
4. Maximum allowable temperature of hot water + 80⁰С.
5. In order to avoid any mechanical impurities (abrasive particles) getting into the product,
it is recommended to install filters of 100-300 microns.