influence the weighing performance. If the weighing remains stable for longer
than 2s, the scale will finish "0.0kg"calibration automatically, it will then begin
the next calibration point; otherwise, "0.0kg" will keep flickering to wait for the
scale to stabilize.
f) Suppose that the next calibration point should be"xx.xkg", the window will
display "Load"and"xx.xkg" alternately,which means that the weight"xx.xkg"(
WEIGHT)should be loaded on the platform. If you have to change this weight,
you can press
button to change the flashing position and press
flashing position's number plus 1, and press
modification is finished;
g) After making sure the weight on the platform is "xx.xkg", press
to confirm so that the scale begins the "xx.xkg"calibration. In the process
of"xx.xkg" calibration, "xx.xkg" flickers rapidly on the display window;keep the
platform calm, stable, and without other interference factors which will
influence the weighing performance. If the weighing remains stable for more
than 2s, the scale will finish "xx.xkg"calibration and save the calibrated
parameters, then will return to the weighing mode; otherwise, "xx.xkg"will keep
flickering until the scale stable
6.4.2 Standard Two Point Weight Calibration
a) At weighing mode, press and hold
----";
b) Press
or
displays"Line";
c) Press
button to begin calibration procedure;
d) After the scale begins to calibrate, the window will display"Load"and"0.0kg"
alternately;
e) After you confirm that there is nothing on the platform, press
to confirm and begin the zero calibration when the window displays"0.0kg". In
the process of zero calibration, "0.0kg"flickers rapidly on the display window;
please keep the platform calm, stable, and without other interference factors
which will influence the weighing performance. If the weighing keeps stable
exceeding 2s, the scale will finish zero calibration automatically, and then it will
ANYLOAD ES310 Postal & Shipping Scale User's Manual (V1611)
5 |
or
button to enter the modify menu; then press
button cycle the display until the window
button to make the
button to make sure the
button until the window displays"--
button
button