3onedata CP202-2CI Manual de instalación rápida - Página 2
Navegue en línea o descargue pdf Manual de instalación rápida para Servidor 3onedata CP202-2CI. 3onedata CP202-2CI 3 páginas. Can server
También para 3onedata CP202-2CI: Manual del usuario (4 páginas)
supply specification to avoid over-voltage damaging
the device.
【Wall-mounted Device Disassembling】
Step 1
Screw out the bolt in the wall.
Step 2
Lift the device outward slightly; take out the device,
disassembling ends.
【Power Supply Connection】
DC power supply
The device supports 1-way DC power input
(VI+, VI-), 4-pin 5.08mm pitch industrial
wiring terminal blocks, another terminal
block (VO+, VO- ) is reserved. Power supply range: 9~
24VDC.
Note:
1.
Power ON operation: First insert the power supply
terminal block into the device power supply interface,
and then plug the power supply plug contact and power
on.
2.
Power OFF operation: first unpin the power plug, then
remove the terminal block wiring part, please note the
operation order above.
【Restore Default Settings】
DEF is restoring default
settings button. Restoring
default settings steps as
follows: Press and hold
the
disconnect the power supply and then give the device to
power up, wait for about 3~4 seconds to restore the factory
settings.
【CAN Port Connection】
The device has 2-way
CAN-Bus Ports, 10 pins,
1~5 pin are the first
CAN port, 2~10 pin are the second CAN port. CAN-Bus Port
adopts 10 bits 5.08mm pitch industrial wiring terminal block,
and pin define as follow.
NO.
1
2
3
4
5
6
7
8
9
10
【LED Indicator】
The device provides LED indicators to monitor the device
working
status
troubleshooting; the function of each LED is described in the
table as below:
LED
LINK
DEF
button,
RUN
ERR1
ERR2
Name
Description
CAN2L
CAN2 port CANL Signal
CAN2H
CAN2 port CANH Signal
R2ES+
CAN2 port Terminal Resistor
Connector (built-in 120Ω
R2ES-
terminal resistor, direct
connection)
SHELL
Shell Ground
SHELL
Shell Ground
R1ES-
CAN1 port Terminal Resistor
Connector (built-in 120Ω
R1ES+
terminal resistor, direct
connection)
CAN1H
CAN1 port CANH Signal
CAN1L
CAN1 port CANL Signal
with
a
comprehensive
simplified
State
Description
ON
LAN port connection is active
LAN port is in network active
Blinking
status
OFF
LAN port connection is inactive
Blinking
System is running normally
System is not running or
OFF
running abnormally
ON
System is running abnormal
ON
CAN1 port work appears fault
OFF
CAN1 port is working normally
ON
CAN2 port work appears fault
OFF
CAN2 port is working normally
CAN1
OFF
CAN1 port without data
transmission or data
transmission abnormal
Blinking
CAN1 port exists data
transmission
CAN2
OFF
CAN2 port without data
transmission or data
transmission abnormal
Blinking
CAN2 port exists data
transmission
【Logging in to WEB Interface】
This device supports WEB management and configuration.
Computer can access the device via Ethernet interface. The
way of logging in to device's configuration interface via IE
browser is shown as below:
Step 1
Configure the IP addresses of computer and the
device to the same network segment, and the
network between them can be mutually accessed
Step 2
Enter device's IP address in the address bar of
the computer browser.
Step 3
Enter device's username and password in the
login window as shown below.