RECOMMENDED INSTALLATION TOOLS
A
B
A - 3 .5" Hole Saw Bit
B - 3/8" Drill Bit
C - Drill/Power Driver
INSTALLATION REQUIREMENT
1 .
Unit should be installed downstream of
the air handler in the HVAC system .
2 .
The ductwork around the installation
area should be cleaned and dry to
insure proper adhesion of the gasket
materials and any tape used .
3 .
Two circular openings, measuring
approximately 3 .5" (8 .89cm) each, will
need to be cut into the existing duct
work to install the unit properly .
ELECTRICAL REQUIREMENT
To use the 120V plug, be sure to locate the unit within 6 ft . of a standard 120V grounded outlet .
Long term use on an extension cord is not recommended due to safety considerations .
HARDWIRING REQUIREMENT
Permanent wiring of the unit into your HVAC system, or installations using a 220V plug
(not included) should be done by a licensed HVAC Installer or Electrical Contractor only .
For 110V or 220V Applications:
For International Applications:
C
D - Utility Knife
E - Tin Snips
F - Phillips Head Screwdriver
Black = L1, White = Neutral, Green - Ground
Brown = L1, Blue = L2, Green/Yellow = Ground