anytronics Anyscene 512 Manual de instalación y funcionamiento - Página 8

Navegue en línea o descargue pdf Manual de instalación y funcionamiento para Controlador anytronics Anyscene 512. anytronics Anyscene 512 13 páginas. Scene recall unit

6.1. Auto Cycle Mode

To enter the auto cycle mode both the Up and Down buttons should be held for at least
two seconds. On entering this mode, the yellow Data LED will be illuminated until the
buttons are released and the Anyscene 512 will start to cycle round scene memories 1-7
in ascending sequence. Whilst in auto cycle mode the levels and speed can be adjusted
as per section 4.2.
If the Anyscene 512 is powered down whilst in auto cycle mode, when powered up it will
recommence the auto cycle, starting from the scene memory in which it originally started
scene cycling.
Pressing any of the scene select buttons will terminate the auto cycle mode, and the
Anyscene 512 will fade to the selected scene. The unit will also exit auto cycle mode if an
external DMX source becomes active.

6.2. Master / Speed Settings

The Master / Speed DIL switch is used in conjunction with the auto cycle feature of the
Anyscene 512 and can be used to alter the duration and speed of the cycling. As supplied,
with DIL switch 4 set to OFF the default time spent in each scene is approximately 10
seconds
Master / Speed DIL OFF
The Up and Down buttons can be used to adjust the Master level in auto cycle
mode and the setting is reset to maximum when leaving auto cycle mode.
Master / Speed DIL ON
The Up and Down buttons can be used to adjust the cycle Speed in auto cycle
mode. The Up button will speed up the auto cycle and reduce the cycle period to
under 3 seconds. The Down button will reduce the auto cycle speed and increase
the scene cycle period to one minute. This altered setting will normally be
maintained whilst the unit is powered.
To save the adjusted master level and speed settings the following procedure should be
followed,
a) Set the Master Level as required
b) Set the Speed as required
c) Turn the MWP DIL off
d) Turn the Master / Speed DIL off
e) Turn the MWP DIL on
The current Master and cycle time settings are now saved as the power up default, and
Master / Speed DIL can be set to ON or OFF to allow push button control either of Master
level or auto cycle period as required. Note that any time Master / Speed DIL is moved
from ON to OFF with MWP DIL in the OFF position, the current Master level and cycle
speed will be saved as the new power up default.
Units 5 & 6 Hillside Industrial Estate
London Road, Horndean,
Hampshire, PO8 0BL
Tel +44 (0)23 9259 9410
Fax +44(0)23 9259 8723
Page 8 of 13
AT1039 Issue 1
Anyscene 512 Operating
Instructions