ii. Both PAs RF-CTRL-MODE set to Remote mode (disables PA front
iii. Both PAs output power is greater than min threshold (amp_fwd_min) –
c. Notes:
i. In Manual (Local) Mode, the Switch Controller does not monitor the PA
4. Both TXA and TXB Off at the same time: The Switch Controller will not allow both
PAs to be off (or on) at the same time. If this is desired for test purposes, then it can be
accomplished by an onsite engineer by disabling the PA-to-Switch Controller
communications and simply using the PA front panel On/Off buttons for individual PA
control. Simply follow the steps below.
a. Local (onsite): To turn both TXs off (or on) at the same time ...
i. Put both PAs into Local mode by selecting Local on the PA web
ii. Onsite engineer may then control individual PA On/Off via the PA front
b. Remote (via web interface): To turn both TXs off at the same time ...
i. Because the Switch Controller always puts one PA on and into the
RF-SWITCH-USR-DOC-V2.0, 1/6/2017
panel RF On/Off button).
i.e. both PAs are VALID.
output power for a period of roughly 30 seconds to establish VALID or
INVALID – it simply switches instantly upon user command.
interface (this transfers PA on/off control back to the PA front panel
button)
panel button.
antenna and the other TX off and into the load, the only way to turn both
TXs off at the same time remotely is to turn the RF Off on both Exciters.
The Switch Controller will still command one of the two PAs on, but
without drive from the exciter, there will be no output power from either
PA. Be sure to remotely network to both PAs, both Exciters, and the
Switch Controller to have full remote control of the system.