4. Pneumatic Connection

CAUTION !
For a flawless functioning of the pneumatic control procedures the
following points must be observed.
The compressed air supply is to be such that the minimum operating
pressure does not fall below 5 bar , even at the moment of greatest air
consumption.
Connection to the compressed air supply occurs through accessories
available as optional equipment ( 797 003031 ) or with
customer-supplied connection materials.
Operating pressure 2 = 6 bar
The blower pressure 1 must be adjusted to the material.
Standard setting: approx. 3 bar
To set the pressure lift the appropriate knob and turn.
Turn to the left
Turn to the right
= Decrease pressure
= Increase pressure