3.2 Wiring and connecting the cable to the control unit
2
B
Ausgabe/Edition:
Änderungsindex
03.2011
Rev. index: 00.0
Anbauanleitung für Barcodeleser
Teilesatz 0911 597554
Fitting Instructions Barcode Reader
Kit 0911 597554
1
Conduct the cable 2 (1.9 m of 9870 911016) from A to B parallel
to the cable harness 3 and attach it with several cable ties 4 to
it.
Connect the white and the black core with the spring clamp of
the power supply unit 1.
Black to SW (0V)
White to WS (+ VCC)
6
5
Plug the plug 6 with the level converter 5 into the socket X150b
on the control unit and secure it with screws.
A
Printed in Germany
Teile-Nr./ Part-No.:
0791 911702
4
4
3
3
Blatt:
von