Duerkopp Adler 0791 911703 Manual de instrucciones de montaje - Página 17

Navegue en línea o descargue pdf Manual de instrucciones de montaje para Monitor Duerkopp Adler 0791 911703. Duerkopp Adler 0791 911703 20 páginas. Remaining thread monitor

Duerkopp Adler 0791 911703 Manual de instrucciones de montaje
Fitting Instruction for Remaining Thread Monitor
3
Operating
3.1 Winding on the bobbin thread
3.2 Activating the residual thread monitor
Ausgabe/Edition:
Änderungsindex
03.2011
Rev. index: 00.0
Anbauanleitung Restfadenwächter
Teilesatz 0911 597754
Kit 0911 597754
The residual tread monitor bobbins have to be inserted for
winding on with the groove A pointing towards the winder, so
that the groove A is not visible.
The thread has to be wound on into the small bobbin segment
first.
The bobbin has to be inserted in the hook with the groove A
pointing downwards!
(Also see the operating manual chapter 7.7.4: Edit the machine
parameters)
Select "MP1 – Configuration" in "Machine parameters".
Then select "Options" (MP1.4) and activate the bobbin thread
monitor.
A
Printed in Germany
Teile-Nr./ Part-No.:
0791 911703
Blatt:
von