Fitting Instruction for Remaining Thread Monitor
3
Operating
3.1 Winding on the bobbin thread
3.2 Activating the residual thread monitor
Ausgabe/Edition:
Änderungsindex
03.2011
Rev. index: 00.0
Anbauanleitung Restfadenwächter
Teilesatz 0911 597754
Kit 0911 597754
–
The residual tread monitor bobbins have to be inserted for
winding on with the groove A pointing towards the winder, so
that the groove A is not visible.
–
The thread has to be wound on into the small bobbin segment
first.
–
The bobbin has to be inserted in the hook with the groove A
pointing downwards!
(Also see the operating manual chapter 7.7.4: Edit the machine
parameters)
–
Select "MP1 – Configuration" in "Machine parameters".
–
Then select "Options" (MP1.4) and activate the bobbin thread
monitor.
A
Printed in Germany
Teile-Nr./ Part-No.:
0791 911703
Blatt:
von
Sheet: 17 from 20