The rack supports 2 power supply modules
optional, single and dual power supply optional. As
for dual power supply device, if one power supply
fails, it will immediately switch to another power
supply, ensuring uninterrupted power supply of the device.
Power supply input range: 100~250VAC.
DC power supply input
The rack supports 2 power supply modules
optional, single and dual power supply
optional. DC power supply adopts 2 terminal
blocks, power supply input: -48VDC. The pin definition as
follows:
Pin NO.
1
Pin definition
-48VDC+
Note:
Power ON operation: First insert the power supply
terminal block into the device power supply interface,
and then plug the power supply plug contact and power
on.
Power OFF operation: first unpin the power plug, and
then remove the terminal block wiring part, please note
the operation order above.
【Indicator】
The device provides LED indicators to monitor the device
operating
status,
comprehensively
troubleshooting, each indicator's detailed status as the table
below:
LED
Status
Power supply is operating
ON
POWER
normally
(1-2)
Power supply is disconnected or
OFF
abnormal
【Specifications】
Panel
Card slot
Indicator
Power supply
Input power supply
Output power supply
Consumption
Full-load consumption
Environment Limits
Operating temperature
Storage temperature
Operating humidity
2
-48VDC-
simplifying
the
Description
16 daughter card slots, 2 power
supply module slots
Power supply indicator
100~250VAC or -48VDC
optional
5.7VDC
≤ 50W
0~55℃
-20~75℃
5%~95% (no condensation)