13.
Make sure there is enough free space for
shaft beneath the housing. Minimum 100
mm (3,94 inch). Carefully lower cylinder
barrel into housing.
WARNING:
If cylinder barrel is dropped or lowered
too fast into housing, the shaft bearing
might be damaged.
Replacement of the shaft bearing can then
only be done at Danfoss DK- Nordborg.
15.
Place the 7 springs and 3 pins in cylinder
barrel. The pin holes are assymetric.
17.
Place retainer plate in cylinder barrel.
(Remember to lubricate the retainer plate
and cylinder bushings with clean filtered
water).
180R9228 / 521B1181 / DKCFN.PI.013.A2.02 / 10.2013
14.
Unscrew M8 eye bolt.
16.
Place the spring guide and the retainer
guide on the cylinder shaft.
18.
Ensure that retainer plate is oriented
correctly, with its slant surfaces pointing
downwards.