Instruction
Changing pistons APP 11-13 and APP 16-22
3.
Unscrew the remaining 3 screws using the
combination wrench and turn each screw a
couple of rounds at the time, to ensure the
swash plate is loosened as straight
backwards as possible.
Note: There is nothing to hold the swash plate!
5.
Place the swash plate upside down to avoid
scratches on the surface.
180R9227 / 521B1194 / DKCFN.PI.013.O1.02 / 03.2012
4.
Remove the flange/swash plate carefully.
6.
Carefully remove the pistons one by one.