Danfoss APPW 5.1 Manual de servicio - Página 7

Navegue en línea o descargue pdf Manual de servicio para Bomba de agua Danfoss APPW 5.1. Danfoss APPW 5.1 12 páginas. Disassembling and assembling

Danfoss APPW 5.1 Manual de servicio
Service guide | Disassembling and Assembling, APP(W) 5.1-10.2

4. Assembling swash plate

© Danfoss | DCS (im) | 2017.06
3. Remove the swash plate and the spacer.
1. Replace the O-rings.
3. Position the swash plate on the mounting
flange using the guide pins and fix it with
the screw.
2. Mount the spacer on the swash plate.
4. The mounting flange is now ready to be
mounted on the housing.
180R9238 | DKCFN.PI.078.F3.02 | 521B1196 | 7